6.7 Performing a Diagnosis Test
6.7 Performing a Diagnosis Test
This section describes the procedure for performing an initial diagnosis of hardware before system startup.
Note - The SPARC M12-2S is powered on and off during the diagnosis test. A CPU Activation key does not need to have been registered for power-on during the diagnosis test at this point. |
- Execute the testsb command.
The testsb command performs an initial diagnosis of hardware.
During the diagnosis, the SPARC M12-2S is powered on and off. By specifying options, you can check whether HDD/SSD/PCIe cards are mounted. You can also check the crossbar cable connections in a building block configuration.
The following example performs an initial diagnosis and connection I/O check of the SPARC M12-2S.
<Description of options specified>-v: Additionally displays detailed messages of the initial diagnosis-p: Executes the "probe-scsi-all" command of OpenBoot PROM and displays the results while a diagnosis is being processed. If the PCI expansion unit is connected, the execution results of the ioxadm -v list command of the XSCF are displayed.-s: Executes the "show-devs" command of OpenBoot PROM and displays the results while a diagnosis is being processed. If the PCI expansion unit is connected, the execution results of the ioxadm -v list command of the XSCF are displayed.-a: Diagnoses all the mounted hardware resources-y: Automatically responds with "y" to a query
XSCF> testsb -a -v -p -s Initial diagnosis is about to start, Continue?[y|n] :y PSB power on sequence started. POST Sequence 01 Banner LSB#00: POST 5.6.0 (2016/08/25 09:01) LSB#01: POST 5.6.0 (2016/08/25 09:01) : <<Displayed execution results of "probe-scsi-all">> /pci@8d00/pci@4/pci@0/pci@0/scsi@0 FCode Version 1.00.56, MPT Version 2.00, Firmware Version 20.00.00.00 Target a Unit 0 Encl Serv device FUJITSU BBEXP 0d32 SASAddress 500000e0e0b001bd PhyNum 14 /pci@8900/pci@4/pci@0/pci@0/scsi@0 FCode Version 1.00.56, MPT Version 2.00, Firmware Version 20.00.00.00 Target a Unit 0 Disk TOSHIBA AL13SEB600 3702 1172123568 Blocks, 600 GB SASDeviceName 50000395881893e0 SASAddress 50000395881893e2 PhyNum 0 Target b Unit 0 Encl Serv device FUJITSU BBEXP 0d32 SASAddress 500000e0e0b001bd PhyNum 14 : <<Displayed execution results of "show-devs">> /pci-performance-counters@8f00 /pci-performance-counters@8e00 /pci-performance-counters@8d00 : <<Displayed execution results of "ioxadm versionlist" and "ioxadm -v list">> -------------------------------------------------------------------------------- [PCIBOX Versions] PCIBOX Ver Link Ver Info PCIBOX#2001 5220 BB#00-PCI#04 5220 equal -------------------------------------------------------------------------------- [PCIBOX Informations] Location Type FW Ver Serial Num Part Num State PCIBOX#2001 PCIBOX - 2121212001 On PCIBOX#2001/PSU#1 PSU - FEJD1201000169 CA01022-0750-D/ On PCIBOX#2001/IOB IOBOARD 5220 PP122300JW CA20365-B66X 007AF On PCIBOX#2001/LINKBD BOARD - PP123300TR CA20365-B60X 001AA On PCIBOX#2001/FANBP FANBP - PP120904SY CA20365-B68X 004AC On BB#00-PCI#04 CARD 5220 PP13490467 CA20365-B59X 013AD/9999999 On -------------------------------------------------------------------------------- PSB power off sequence started. [1200sec] 0..... 30..... 60..... 90end PSB powered off. PSB Test Fault ---- ------- -------- 00-0 Passed Normal 01-0 Passed Normal XSCF> |
- Check the execution results of "probe-scsi-all" to confirm that all mounted internal storage (HDD/SSD) is identified.
- Check the execution results of "show-devs" to confirm that all mounted PCIe cards are recognized.
- If a PCI expansion unit is connected, you can confirm the serial number and firmware version number of the PCI expansion unit from the execution results of "ioxadm -v list".
- Confirm that "Passed" and "Normal" appear for BB#00 (PSB 00-0) in the results of the initial diagnosis.
If the results display anything other than the above, see "Appendix A Troubleshooting."
< Previous Page | Next Page >