Skip to main content

6.7 Performing a Diagnosis Test


6.7 Performing a Diagnosis Test
This section describes the procedure for performing an initial diagnosis of hardware before system startup.
Note - The SPARC M12-2S is powered on and off during the diagnosis test.
A CPU Activation key does not need to have been registered for power-on during the diagnosis test at this point.
  1. Execute the testsb command.
    The testsb command performs an initial diagnosis of hardware.
    During the diagnosis, the SPARC M12-2S is powered on and off. By specifying options, you can check whether HDD/SSD/PCIe cards are mounted. You can also check the crossbar cable connections in a building block configuration.

    The following example performs an initial diagnosis and connection I/O check of the SPARC M12-2S.
    <‌Description of options specified>‌
    -v: Additionally displays detailed messages of the initial diagnosis

    -p: Executes the "probe-scsi-all" command of OpenBoot PROM and displays the results while a diagnosis is being processed. If the PCI expansion unit is connected, the execution results of the ioxadm -v list command of the XSCF are displayed.

    -s: Executes the "show-devs" command of OpenBoot PROM and displays the results while a diagnosis is being processed. If the PCI expansion unit is connected, the execution results of the ioxadm -v list command of the XSCF are displayed.

    -a: Diagnoses all the mounted hardware resources

    -y: Automatically responds with "y" to a query
XSCF> testsb -a -v -p -s
Initial diagnosis is about to start, Continue?[y|n] :y
PSB power on sequence started.
POST Sequence 01 Banner
LSB#00: POST 5.6.0 (2016/08/25 09:01)
LSB#01: POST 5.6.0 (2016/08/25 09:01)
:
<<Displayed execution results of "probe-scsi-all">>
/pci@8d00/pci@4/pci@0/pci@0/scsi@0

FCode Version 1.00.56, MPT Version 2.00, Firmware Version 20.00.00.00

Target a
Unit 0 Encl Serv device FUJITSU BBEXP 0d32
SASAddress 500000e0e0b001bd PhyNum 14

/pci@8900/pci@4/pci@0/pci@0/scsi@0

FCode Version 1.00.56, MPT Version 2.00, Firmware Version 20.00.00.00

Target a
Unit 0 Disk TOSHIBA AL13SEB600 3702 1172123568 Blocks, 600 GB
SASDeviceName 50000395881893e0 SASAddress 50000395881893e2 PhyNum 0
Target b
Unit 0 Encl Serv device FUJITSU BBEXP 0d32
SASAddress 500000e0e0b001bd PhyNum 14
:
<<Displayed execution results of "show-devs">>
/pci-performance-counters@8f00
/pci-performance-counters@8e00
/pci-performance-counters@8d00
:
<<Displayed execution results of "ioxadm versionlist" and "ioxadm -v list">>
--------------------------------------------------------------------------------

[PCIBOX Versions]
PCIBOX Ver Link Ver Info
PCIBOX#2001 5220 BB#00-PCI#04 5220 equal
--------------------------------------------------------------------------------

[PCIBOX Informations]
Location Type FW Ver Serial Num Part Num State
PCIBOX#2001 PCIBOX - 2121212001 On
PCIBOX#2001/PSU#1 PSU - FEJD1201000169 CA01022-0750-D/ On
PCIBOX#2001/IOB IOBOARD 5220 PP122300JW CA20365-B66X 007AF On
PCIBOX#2001/LINKBD BOARD - PP123300TR CA20365-B60X 001AA On
PCIBOX#2001/FANBP FANBP - PP120904SY CA20365-B68X 004AC On
BB#00-PCI#04 CARD 5220 PP13490467 CA20365-B59X 013AD/9999999 On
--------------------------------------------------------------------------------

PSB power off sequence started. [1200sec]
0..... 30..... 60..... 90end
PSB powered off.
PSB Test Fault
---- ------- --------

00-0 Passed Normal
01-0 Passed Normal
XSCF>
  1. Check the execution results of "probe-scsi-all" to confirm that all mounted internal storage (HDD/SSD) is identified.
  2. Check the execution results of "show-devs" to confirm that all mounted PCIe cards are recognized.
  3. If a PCI expansion unit is connected, you can confirm the serial number and firmware version number of the PCI expansion unit from the execution results of "ioxadm -v list".
  4. Confirm that "Passed" and "Normal" appear for BB#00 (PSB 00-0) in the results of the initial diagnosis.
    If the results display anything other than the above, see "Appendix A Troubleshooting."