C.1.2 deleteboard
C.1.2 deleteboard
- A hardware error occurred. Please check the error log for details.
[Meaning] The command terminated due to a hardware error.
[Action] Check the error log for the possible fault location, and replace the faulty component. - An internal error has occurred. Please contact your system administrator.
[Meaning] An internal error has occurred. Contact the system administrator.
[Action] An error or XSCF internal resource shortage may have occurred in a library in use in XSCF. Wait for a while, and then perform the operation again. If the error occurs again, contact a Fujitsu field engineer to have the error investigated. - Cannot communicate with Hypervisor or Logical Domains Manager. Please check the domain's state.
[Meaning] An error occurred in the communication with Hypervisor or Logical Domains Manager.
[Action] From the monitoring messages and console messages output, determine the cause of the failure of the dynamic reconfiguration in Oracle Solaris of the logical domain or Logical Domains Manager. Then, eliminate the cause, and perform the operation again. - Cannot communicate with XXX. Please check XXX's state.
[Meaning] The standby or slave XSCF has an error.
[Action] Resolve the error of the standby or slave XSCF. This error does not occur in the SPARC M12/M10 system with the one-unit configuration. - Control domain is stopped for CoD resource violation.
[Meaning] Because the control domain stopped due to a violation of CPU Activation, the specified PSB (BB) could not be released.
[Action] Resolve the CPU Activation violation, and then perform the operation again. - DR operation canceled by operator.
[Meaning] Dynamic reconfiguration was canceled because the user issued an instruction to stop it. - Invalid parameter.
[Meaning] Parameter error
[Action] Check the arguments and the operand. - Operation has completed.
[Meaning] Release has completed. - Operation is continued as "no".
[Meaning] The operation that applies when [n] is selected was performed because the correct operation was not executed in response to the [y|n] prompt.
[Action] Check the system board (PSB) information. If there is a PSB that needs to be released, release it again. - Operation not supported on this system.
[Meaning] The entered command is not supported by the system.
[Action] Check the model and the XCP version to find out whether the command can be executed. - Permission denied.
[Meaning] You do not have access privilege. Or, you attempted to execute other than an executable command on the standby XSCF, resulting in an execution privilege error.
[Action] Compare your user privileges and the execution privilege required for the command. - PPAR DR function setting is disabled.
[Meaning] Dynamic reconfiguration cannot be performed because the PPAR DR function is disabled.
[Action] Check the PPAR DR function setting, and perform the operation again. - PPAR is currently unavailable for DR, because XBU status has failed.
[Meaning] Dynamic reconfiguration cannot be performed because there is an error in either the crossbar unit (XBU) of a specified physical partition or system board (PSB), or the crossbar unit of a configured crossbar box.
[Action] Check the monitoring messages and the error log to confirm that the relevant crossbar unit does not have an error. If it has an error, identify the faulty component and replace it. - PPAR (PPAR-ID XX) is currently unavailable for DR, because another operation is in progress. Try again later.
[Meaning] Dynamic reconfiguration cannot be performed because the specified physical partition is being accessed by another operation.
[Action] The power may be off in another session, or an operation to change the configuration information of the connected PCI expansion unit may be underway in another session. Wait for a while checking the status of the physical partition, and then perform the operation again. - PPAR (PPAR-ID XX) is not currently running.
[Meaning] You specified the -c unassign or -c disconnect option, but the release failed because the destination physical partition was not operating.
[Action] Check the operation status of the physical partition. - PSB power off sequence started.
[Meaning] Power off of the power supply of the PSB (BB) has started. - PSB#XX-X can not be unconfigured because there is Hypervisor global memory.
[Meaning] The specified PSB cannot be released because the hypervisor memory needs to be relocated. - PSB#XX-X could not be unconfigured from PPAR-ID XX due to Hypervisor error.
[Meaning] Release failed due to a dynamic reconfiguration error returned by the hypervisor.
[Action] From the monitoring messages and console messages output, determine the cause of the failure of the dynamic reconfiguration in Oracle Solaris of the logical domain or Logical Domains Manager. Then, eliminate the cause, and perform the operation again. - PSB#XX-X could not be unconfigured from PPAR-ID XX due to operating system or Logical Domains Manager error.
[Meaning] Release failed due to a dynamic reconfiguration error returned by Oracle Solaris of the logical domain or Logical Domains Manager.
[Action] From the monitoring messages and console messages output, determine the cause of the failure of the dynamic reconfiguration in Oracle Solaris of the logical domain or Logical Domains Manager. Then, eliminate the cause, and perform the operation again. - PSB#XX-X has not been registered in PCL.
[Meaning] The operation could not be performed because the specified PSB is not registered in the physical partition (PPAR) configuration information.
[Action] Register the physical partition (PPAR) configuration information, and then perform the operation. - PSB#XX-X is currently unavailable for DR. Try again later.
[Meaning] Dynamic reconfiguration cannot be performed because the specified PSB is being accessed by another operation.
[Action] It is possible that dynamic reconfiguration, start/stop of the physical partition, or maintenance work is being performed in another session. Check the status of the PSB, wait for a while, and then perform the operation again. - PSB#XX-X is not installed.
[Meaning] The operation could not be performed because the specified PSB is not mounted.
[Action] You may have specified the wrong PSB. Check the status of the PSB. - PSB#XX-X is the last LSB for PPAR-ID XX, and this PPAR is still running. Operation failed.
[Meaning] The specified PSB (BB) cannot be removed from the configuration because it is the last PSB (BB) that constitutes the physical partition.
[Action] Perform the operation after stopping the physical partition, or stop the physical partition by specifying the -c reserve option. - PSB#XX-X status is FAILED.
[Meaning] The specified PSB (BB) could not be released because its status is failed.
[Action] Check the monitoring messages and the error log to confirm that the hardware does not have an error. If it has an error, identify the faulty component and replace it. - PSB#XX-X will be unassigned from PPAR after the PPAR restarts. Continue? [y|n] :
[Meaning] Release of PSB number XX-X from the physical partition following the restart of the physical partition will be reserved. Do you want to continue? - PSB#XX-X will be unassigned from PPAR immediately. Continue?[y|n] :
[Meaning] PSB number XX-X will be released from the physical partition. Do you want to continue? Enter "y" to continue, and enter "n" to cancel. - PSB#XX-X will be unconfigured from PPAR immediately. Continue?[y|n] :
[Meaning] PSB number XX-X will be released from the physical partition, and will be in the assigned state. Do you want to continue? Enter "y" to continue, and enter "n" to cancel. - Start unconfigure preparation of PSB.
[Meaning] Preparation of PSB (BB) release has started. - Start unconfiguring PSB from PPAR.
[Meaning] Release process of PSB (BB) has started. - System may be temporarily suspended, proceed?[y|n] :
[Meaning] The system will be temporarily suspended. Do you want to continue? Enter "y" to continue, and enter "n" to cancel. - The current configuration does not support this operation.
[Meaning] The command terminated due to a configuration error.
[Action] Check the hardware installation status and the functional settings required for the command execution. - The other XSCF is currently unavailable for DR. Try again later.
[Meaning] Dynamic reconfiguration cannot be performed because the standby or slave XSCF is being shut down.
[Action] The standby or slave XSCF may be shutting down. Perform dynamic reconfiguration again checking the status of the standby or slave XSCF. - The system is currently unavailable for DR, because another operation is in progress. Try again later.
[Meaning] Dynamic reconfiguration cannot be performed because an operation for the entire SPARC M12/M10 system is being performed.
[Action] The firmware may be undergoing update in another session. After the firmware is completely updated, perform dynamic reconfiguration again. - There is no available action for the following resources.
Or,
DR operation would require shutting down domains, use force to proceed
[Meaning] A physical I/O device of the system board (PSB) to be deleted may be assigned to a logical domain.
[Action] Execute the ldm list-io command from the control domain to check the assignment status of the relevant physical I/O device. If the relevant physical I/O device is assigned to a logical domain, use the ldm remove-io command to delete it. - Timeout detected during communicate with Logical Domains Manager.
[Meaning] A timeout occurred in the communication with Logical Domains Manager.
[Action] From the monitoring messages and console messages output, determine the cause of the failure of the dynamic reconfiguration in Oracle Solaris of the logical domain or Logical Domains Manager. Then, eliminate the cause, and perform the operation again. - Timeout detected during poweroff.
[Meaning] The system board (PSB) power-off processing of dynamic reconfiguration timed out before completion.
[Action] Confirm that the hardware has not failed. If it has an error, identify the faulty component and replace it. - Timeout detected during unconfiguration of PSB#XX-X.
[Meaning] Release of dynamic reconfiguration timed out before completion.
[Action] Check the monitoring messages and the error log to confirm that the hardware does not have an error. If it has an error, identify the faulty component and replace it. - Unconfigure preparation of PSB has completed.
[Meaning] Preparation of PSB (BB) release has completed. - Unconfigured PSB from PPAR.
[Meaning] PSB (BB) release has completed.