C.1.1 addboard
C.1.1 addboard
- A hardware error occurred. Please check the error log for details.
[Meaning] The command terminated due to a hardware error.
[Action] Check the error log for the possible fault location, and replace the faulty component. - An internal error has occurred. Please contact your system administrator.
[Meaning] An internal error has occurred. Contact the system administrator.
[Action] An error or XSCF internal resource shortage may have occurred in a library in use in XSCF. Wait for a while, and then perform the operation again. If the error occurs again, contact a Fujitsu field engineer to have the error investigated. - Another DR operation is in progress. Try again later.
[Meaning] Cannot access the specified physical partition because it is undergoing dynamic reconfiguration in another session.
[Action] Dynamic reconfiguration is in progress in another session. Check the status of the physical partition, wait for a while, and then perform the operation again. - Cannot communicate with Hypervisor or Logical Domains Manager. Please check the domain's state.
[Meaning] An error occurred in the communication with Hypervisor or Logical Domains Manager.
[Action] From the monitoring messages and console messages output, determine the cause of the failure of the dynamic reconfiguration in Oracle Solaris of the logical domain or Logical Domains Manager. Then, eliminate the cause, and perform the operation again. - Cannot communicate with XXX. Please check XXX's state.
[Meaning] The standby or slave XSCF has an error.
[Action] Resolve the error of the standby or slave XSCF. This error does not occur in the SPARC M12/M10 system with the one-unit configuration. - Configured PSB to Logical Domains (LDoms) Manager.
[Meaning] Incorporation into Logical Domains Manager has completed. - Connected PSB to PPAR.
[Meaning] Incorporation into the physical partition configuration has completed. - Control domain is stopped for CoD resource violation.
[Meaning] The specified system board could not be incorporated into the physical partition because the control domain stopped due to a violation of CPU Activation.
[Action] Resolve the CPU Activation violation, and then perform the operation again. - DR operation canceled by operator.
[Meaning] Dynamic reconfiguration was canceled because the user issued an instruction to stop it. - Initial diagnosis has completed.
[Meaning] Hardware diagnosis has completed. - Initial diagnosis started.
[Meaning] Hardware diagnosis has started. - Invalid parameter.
[Meaning] Parameter error
[Action] Check the arguments and the operand. - Operation has completed.
[Meaning] Incorporation has completed. - Operation is continued as "no".
[Meaning] The operation that applies when [n] is selected was performed because the correct operation was not executed in response to the [y|n] prompt.
[Action] Check the system board (PSB) information. If there is a PSB that needs to be incorporated, incorporate it again. - Operation not supported on this system.
[Meaning] The entered command is not supported by the system.
[Action] Check the model and the XCP version to find out whether the command can be executed. - Permission denied.
[Meaning] You do not have access privilege. Or, you attempted to execute other than an executable command on the standby XSCF, resulting in an execution privilege error.
[Action] Compare your user privileges and the execution privilege required for the command. - PPAR DR function setting is disabled.
[Meaning] Dynamic reconfiguration cannot be performed because the PPAR DR function is disabled.
[Action] Check the PPAR DR function setting, and perform the operation again. - PPAR is currently unavailable for DR, because XBU status has failed.
[Meaning] Dynamic reconfiguration cannot be performed because there is an error in either the crossbar unit (XBU) of a specified physical partition or system board (PSB), or the crossbar unit of a configured crossbar box.
[Action] Check the monitoring messages and the error log to confirm that the relevant crossbar unit does not have an error. If it has an error, identify the faulty component and replace it. - PPAR (PPAR-ID XX) is currently unavailable for DR, because another operation is in progress. Try again later.
[Meaning] Dynamic reconfiguration cannot be performed because the specified physical partition is being accessed by another operation.
[Action] The power may be off in another session, or an operation to change the configuration information of the connected PCI expansion unit may be underway in another session. Wait for a while checking the status of the physical partition, and then perform the operation again. - PPAR (PPAR-ID XX) is not currently running.
[Meaning] You specified the -c configure option, but the incorporation failed because the destination physical partition was not operating.
[Action] Check the operation status of the physical partition, or specify the -c assign option. - PSB#XX-X could not be configured into PPAR-ID XX due to operating system or Logical Domains Manager error.
[Meaning] Incorporation failed due to a dynamic reconfiguration error returned by Oracle Solaris of the logical domain or Logical Domains Manager.
[Action] From the monitoring messages and console messages output, determine the cause of the failure of the dynamic reconfiguration in Oracle Solaris or Logical Domains Manager. Eliminate the cause, and perform the operation again. - PSB#XX-X encountered a hardware error. See error log for details.
[Meaning] Hardware diagnosis of dynamic reconfiguration has detected an error. The hardware may have an error.
[Action] Check the monitoring messages and the error log to confirm that the hardware does not have an error. If it has an error, identify the faulty component and replace it. - PSB#XX-X has not been registered in PCL.
[Meaning] The operation could not be performed because the specified system board is not registered in the physical partition (PPAR) configuration information.
[Action] Register the physical partition (PPAR) configuration information, and then perform the operation. - PSB#XX-X is already assigned to another PPAR.
[Meaning] The specified PSB could not be incorporated into the specified physical partition because it is assigned to another physical partition.
[Action] The PSB is assigned to another physical partition. Check the status of the PSB. - PSB#XX-X is currently unavailable for DR. Try again later.
[Meaning] Dynamic reconfiguration cannot be performed because the specified PSB is being accessed by another operation.
[Action] It is possible that dynamic reconfiguration, start/stop of the physical partition, or maintenance work is being performed in another session. Check the status of the PSB, wait for a while, and then perform the operation again. - PSB#XX-X is not installed.
[Meaning] The operation could not be performed because the specified PSB is not mounted.
[Action] You may have specified the wrong PSB. Check the status of the system board. - PSB#XX-X status is FAILED.
[Meaning] The status of the specified PSB is failed.
[Action] Check the monitoring messages and the error log to confirm that the hardware does not have an error. If it has an error, identify the faulty component and replace it. - PSB#XX-X will be assigned to PPAR-ID XX. Continue?[y|n] :
[Meaning] PSB number XX-X will be assigned to physical partition YY. Do you want to continue? Enter "y" to continue, and enter "n" to cancel. - PSB#XX-X will be configured into PPAR-ID XX. Continue?[y|n] :
[Meaning] PSB number XX-X will be incorporated to physical partition YY. Do you want to continue? Enter "y" to continue, and enter "n" to cancel. - Start configuring PSB to Logical Domains (LDoms) Manager.
[Meaning] Incorporation into Logical Domains Manager has started. - Start connecting PSB to PPAR.
[Meaning] Incorporation into the physical partition has started. - The current configuration does not support this operation.
[Meaning] The command terminated due to a configuration error.
[Action] Check the hardware installation status and the functional settings required for the command execution. - The other XSCF is currently unavailable for DR. Try again later.
[Meaning] Dynamic reconfiguration cannot be performed because the standby or slave XSCF is being shut down.
[Action] The standby or slave XSCF may be shutting down. Perform dynamic reconfiguration again checking the status of the standby or slave XSCF. - The system is currently unavailable for DR, because another operation is in progress. Try again later.
[Meaning] Dynamic reconfiguration cannot be performed because an operation for the entire SPARC M12/M10 system is being performed.
[Action] The firmware may be undergoing update in another session. After the firmware is completely updated, perform dynamic reconfiguration again. - Timeout detected during communicate with Logical Domains Manager.
[Meaning] A timeout occurred in the communication with Logical Domains Manager.
[Action] From the monitoring messages and console messages output, determine the cause of the failure of the dynamic reconfiguration in Oracle Solaris of the logical domain or Logical Domains Manager. Then, eliminate the cause, and perform the operation again. - Timeout detected during configuration into PPAR-ID XX.
[Meaning] Incorporation timed out before completion.
[Action] From the monitoring messages and console messages output, determine the cause of the failure of the dynamic reconfiguration in Oracle Solaris or Logical Domains Manager. Eliminate the cause, and perform the operation again. - Timeout detected during self-test of PSB#XX-X.
[Meaning] Hardware diagnosis of dynamic reconfiguration timed out before completion. The hardware may have an error.
[Action] Check the monitoring messages and the error log to confirm that the hardware does not have an error. If it has an error, identify the faulty component and replace it.