7.4.2 Inactive Maintenance


7.4.2 Inactive Maintenance
You can perform inactive maintenance only for a system that uses the SPARC M10-4S in a building block configuration.
This section describes the flows of the inactive replacement, inactive addition, and inactive removal of the link card.
References to detailed descriptions are written in the work procedure tables. See any of them as required.
The following patterns are available for inactive maintenance of the link card.
Inactive Replacement (Replacing the Link Card After Stopping the Physical Partition)
Stop the physical partition in which the link card requiring maintenance is mounted, and then replace the link card.
Figure 7-20  Inactive Replacement Flow (Replacing the Link Card After Stopping the Physical Partition)
Figure 7-20  Inactive Replacement Flow (Replacing the Link Card After Stopping the Physical Partition)
Table 7-22  Inactive Replacement Work Procedure (Replacing the Link Card After Stopping the Physical Partition)
Step Task Reference
1 Opening the rack door  
2 Switching the mode switch on the operation panel of the destination server to Service mode "2.3.2 OPNL Control Function" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"5.2 Switching the Mode Switch to Service Mode" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
3 Locating the PCI expansion unit requiring maintenance by causing the CHECK LED (locator) of the unit to blink "5.2 Checking the PCI Expansion Unit Requiring Maintenance and the Destination Physical Partition"
4 Checking the firmware version of the PCI expansion unit "5.3 Checking the Firmware Version of the PCI Expansion Unit"
5 Checking the operating condition of the system and the I/O device usage status "5.4.1 Checking the Operating Condition of the Physical Partition or Logical Domain"
6 Powering Off the Physical Partition Requiring Maintenance "9.5 Stopping the System" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"5.5 Powering Off the Physical Partition Requiring Maintenance" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
7 Enabling access to the FRU requiring maintenance "9.8.1 Lowering the Cable Support" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"5.9.2 Lowering the cable support" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
8 Replacing a faulty link card "Chapter 12 Maintaining PCIe Cards" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"Chapter 8 Maintaining the PCI Express Cards" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
9 Restoring the System "10.1.2 Securing the Cable Support" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.1.2 Fixing the cable support" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
10 Performing a diagnosis test "10.5 Diagnosing a Replacement FRU" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.3.1 Diagnosing the system board" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
11 Confirming that there is no problem with the replacement FRU "10.5.3 Checking the FRU Status After Maintenance" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.3.3 Checking the FRU status after maintenance" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
12 Checking the firmware version and matching it with the pre-replacement one "6.6 Updating the Firmware of the PCI Expansion Unit"
13 Returning the mode switch on the operation panel to Locked mode "2.3.2 OPNL Control Function" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.6 Returning the Mode Switch to Locked Mode" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
14 Powering On the Physical Partition Requiring Maintenance "10.8 Powering on a Physical Partition" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.7 Powering On the Physical Partition Requiring Maintenance" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
15 Closing the rack door  
Inactive Addition (Adding the Link Card After Stopping the Physical Partition)
Stop the physical partition in which the link card is to be added, and then mount the link card.
Figure 7-21  Inactive Addition Flow (Adding the Link Card After Stopping the Physical Partition)
Figure 7-21  Inactive Addition Flow (Adding the Link Card After Stopping the Physical Partition)
Table 7-23  Inactive Addition Work Procedure (Adding the Link Card After Stopping the Physical Partition)
Step Task Reference
1 Opening the rack door  
2 Switching the mode switch on the operation panel of the destination server to Service mode "2.3.2 OPNL Control Function" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"5.2 Switching the Mode Switch to Service Mode" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
3 Locating the PCI expansion unit requiring maintenance by causing the CHECK LED (locator) of the unit to blink "5.2 Checking the PCI Expansion Unit Requiring Maintenance and the Destination Physical Partition"
4 Checking the operating condition of the system and the I/O device usage status "5.4.1 Checking the Operating Condition of the Physical Partition or Logical Domain"
5 Powering Off the Physical Partition Requiring Maintenance "9.5 Stopping the System" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"5.5 Powering Off the Physical Partition Requiring Maintenance" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
6 Enabling access to the FRU requiring maintenance "9.8.1 Lowering the Cable Support" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"5.9.2 Lowering the cable support" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
7 Adding the link card (*1) "Chapter 12 Maintaining PCIe Cards" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"Chapter 8 Maintaining the PCI Express Cards" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
8 Restoring the System "10.1.2 Securing the Cable Support" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.1.2 Fixing the cable support" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
9 Performing a diagnosis test "10.5 Diagnosing a Replacement FRU" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.3.1 Diagnosing the system board" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
10 Confirming that there is no problem with the added FRU "10.5.3 Checking the FRU Status After Maintenance" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.3.3 Checking the FRU status after maintenance" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
11 Checking the firmware version of the PCI expansion unit and updating the firmware as required "6.6 Updating the Firmware of the PCI Expansion Unit"
12 Returning the mode switch on the operation panel to Locked mode "2.3.2 OPNL Control Function" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.6 Returning the Mode Switch to Locked Mode" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
13 Powering On the Physical Partition Requiring Maintenance "10.8 Powering on a Physical Partition" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.7 Powering On the Physical Partition Requiring Maintenance" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
14 Closing the rack door  
*1 For details on the work for adding a PCI expansion unit, see the Installation Guide for your server.
Inactive Removal (Removing the Link Card After Stopping the Physical Partition)
Stop the physical partition from which the link card is to be removed, and then remove the link card.
Figure 7-22  Inactive Removal Flow (Removing the Link Card After Stopping the Physical Partition)
Figure 7-22  Inactive Removal Flow (Removing the Link Card After Stopping the Physical Partition)
Table 7-24  Inactive Removal Work Procedure (Removing the Link Card After Stopping the Physical Partition)
Step Task Reference
1 Opening the rack door  
2 Switching the mode switch on the operation panel of the destination server to Service mode "2.3.2 OPNL Control Function" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"5.2 Switching the Mode Switch to Service Mode" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
3 Locating the PCI expansion unit requiring maintenance by causing the CHECK LED (locator) of the unit to blink "5.2 Checking the PCI Expansion Unit Requiring Maintenance and the Destination Physical Partition"
4 Checking the operating condition of the system and the I/O device usage status "5.4.1 Checking the Operating Condition of the Physical Partition or Logical Domain"
5 Powering Off the Physical Partition Requiring Maintenance "9.5 Stopping the System" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"5.5 Powering Off the Physical Partition Requiring Maintenance" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
6 Enabling access to the FRU requiring maintenance "9.8.1 Lowering the Cable Support" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"5.9.2 Lowering the cable support" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
7 Removing the link card "Chapter 12 Maintaining PCIe Cards" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"Chapter 8 Maintaining the PCI Express Cards" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
8 Restoring the System "10.1.2 Securing the Cable Support" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.1.2 Fixing the cable support" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
9 Performing a diagnosis test "10.5 Diagnosing a Replacement FRU" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.3.1 Diagnosing the system board" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
10 Confirming that there is no problem with the replacement FRU "10.5.3 Checking the FRU Status After Maintenance" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.3.3 Checking the FRU status after maintenance" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
11 Returning the mode switch on the operation panel to Locked mode "2.3.2 OPNL Control Function" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.6 Returning the Mode Switch to Locked Mode" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
12 Powering On the Physical Partition Requiring Maintenance "10.8 Powering on a Physical Partition" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.7 Powering On the Physical Partition Requiring Maintenance" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
13 Closing the rack door