3.3.3 Checking Whether the SR-IOV Function is Used
3.3.3 Checking Whether the SR-IOV Function is Used
This section checks whether the SR-IOV function is used.
Note - For details on the PCIe card supporting the SR-IOV function, see "Appendix C Cards That Support SR-IOV" in the Fujitsu SPARC M12 PCI Card Installation Guide or "Appendix B Cards That Support SR-IOV" in the Fujitsu M10/SPARC M10 Systems PCI Card Installation Guide. |
- Log in to the XSCF shell.
- Execute the showlogs command to identify the PCIe card requiring maintenance.
XSCF> showlogs error |
- Connect to the control domain console of the physical partition.
- Execute the ldm list-io command to determine whether the SR-IOV function is being used.
"VF" displayed in [TYPE] indicates that the SR-IOV function is being used.
# ldm list-io NAME TYPE BUS DOMAIN STATUS ---- ---- --- ------ ------ PCIE0 BUS PCIE0 primary IOV PCIE1 BUS PCIE1 primary IOV PCIE2 BUS PCIE2 primary IOV PCIE3 BUS PCIE3 primary IOV PCIE4 BUS PCIE4 primary IOV PCIE5 BUS PCIE5 primary IOV PCIE6 BUS PCIE6 primary IOV PCIE7 BUS PCIE7 primary IOV /BB0/CMUL/NET0 PCIE PCIE0 primary OCC /BB0/CMUL/SASHBA PCIE PCIE0 primary OCC /BB0/PCI0 PCIE PCIE1 primary OCC /BB0/PCI3 PCIE PCIE2 primary EMP /BB0/PCI4 PCIE PCIE2 primary EMP /BB0/PCI7 PCIE PCIE3 primary EMP /BB0/PCI8 PCIE PCIE3 primary EMP /BB0/CMUL/NET2 PCIE PCIE4 primary OCC /BB0/PCI1 PCIE PCIE5 primary EMP /BB0/PCI2 PCIE PCIE5 primary EMP /BB0/PCI5 PCIE PCIE6 primary EMP /BB0/PCI6 PCIE PCIE6 primary EMP /BB0/PCI9 PCIE PCIE7 primary EMP /BB0/PCI10 PCIE PCIE7 primary EMP /BB0/PCI0/IOVNET.PF0 PF PCIE1 primary /BB0/PCI0/IOVNET.PF1 PF PCIE1 primary /BB0/CMUL/NET0/IOVNET.PF0 PF PCIE0 primary /BB0/CMUL/NET0/IOVNET.PF1 PF PCIE0 primary /BB0/CMUL/NET2/IOVNET.PF1 PF PCIE4 primary /BB0/CMUL/NET2/IOVNET.PF0 PF PCIE4 primary /BB0/PCI0/IOVNET.PF0.VF0 VF PCIE1 iodom00 <--SR-IOV function used /BB0/PCI0/IOVNET.PF0.VF1 VF PCIE1 iodom01 <--SR-IOV function used /BB0/PCI0/IOVNET.PF0.VF2 VF PCIE1 iodom02 <--SR-IOV function used |
< Previous Page | Next Page >