5.5.3 Releasing the Link Card or PCIe Card After Stopping the System
5.5.3 Releasing the Link Card or PCIe Card After Stopping the System
Cold maintenance of the PCI expansion unit can be performed after stopping the system.
This section describes the procedure for stopping a system to which the PCI expansion unit is connected.
For details on the procedure, see "Stopping the Entire System" in the Service Manual for your server.
This section describes the procedure for stopping a system to which the PCI expansion unit is connected.
For details on the procedure, see "Stopping the Entire System" in the Service Manual for your server.
Stopping the System With the XSCF Command
- Confirm that the mode switch on the operation panel is in Service mode.
- Log in to the XSCF shell.
- Execute the poweroff command.
- Check that the POWER LED on the operation panel is off.
- Execute the showpparstatus command to confirm that the power to the physical partition is turned off.
- Execute the showdomainstatus command to confirm the operating condition of the logical domain.
Stopping the System From the Operation Panel
- Confirm that the mode switch on the operation panel is in Service mode.
- Press the power switch on the operation panel for 4 seconds or more.
- Check that the POWER LED on the operation panel is off.
- Execute the showpparstatus command to confirm that the power to the physical partition is turned off.
- Execute the showdomainstatus command to confirm the operating condition of the logical domain.