Skip to main content

7.1.2 Cold Replacement


7.1.2 Cold Replacement
This section describes the cold replacement workflow.
References to detailed descriptions are written in the work procedure tables. See any of them as required.
Cold replacement work varies depending on the method of releasing the link card mounted on the destination server. The following are the work patterns.
Cold Replacement (Releasing the Link Card After Stopping the System)
Cold replacement can be performed for all the FRUs mounted on the PCI expansion unit after stopping the system to which the PCI expansion unit is connected. This operation can be done when the connection destination of the PCI expansion unit is the SPARC M12-1/M12-2/M12-2S/M10-1/M10-4/M10-4S.
Figure 7-3  Cold Replacement Flow (Releasing the Link Card After Stopping the System)
Figure 7-3  Cold Replacement Flow (Releasing the Link Card After Stopping the System)
Table 7-5  Cold Replacement Work Procedure (Releasing the Link Card After Stopping the System)
Step Task Reference
1 Opening the rack door  
2 Switching the mode switch on the operation panel of the destination server to Service mode "5.2 Switching the Mode Switch to Service Mode" in the Fujitsu SPARC M12-1 Service Manual
"2.3.2 OPNL Control Function" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"5.2 Switching the Mode Switch to Service Mode" in the Fujitsu M10-1/SPARC M10-1 Service Manual
"5.2 Switching the Mode Switch to Service Mode" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
3 Locating the PCI expansion unit requiring maintenance by causing the CHECK LED (locator) of the unit to blink "5.2 Checking the PCI Expansion Unit Requiring Maintenance and the Destination Physical Partition"
4 Checking the firmware version of the PCI expansion unit, if you are replacing an I/O board "5.3 Checking the Firmware Version of the PCI Expansion Unit"
5 Checking the operating condition of the system and the I/O device usage status "5.4.1 Checking the Operating Condition of the Physical Partition or Logical Domain"
6 Stopping the system "5.5.3 Releasing the Link Card or PCIe Card After Stopping the System"
7 Enabling access to the FRU requiring maintenance "5.7 Accessing a FRU"
8 Replacing a faulty FRU "Chapter 8 Maintaining the PCI Express Cards"
"Chapter 9 Maintaining the Link Board"
"Chapter 11 Maintaining the Link Cables"
"Chapter 12 Maintaining the Management Cable"
"Chapter 13 Maintaining the Power Supply Units"
"Chapter 14 Maintaining the Fan Units"
"Chapter 15 Maintaining the PCI Tray"
"Chapter 16 Maintaining the I/O Board"
"Chapter 17 Maintaining the Fan Backplane"
9 Restoring the PCI expansion unit "6.1 Restoring the Chassis of the PCI Expansion Unit"
10 Performing a diagnosis test "6.4 Diagnosing a Replacement FRU" in the Fujitsu SPARC M12-1 Service Manual
"10.5 Diagnosing a Replacement FRU" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.4 Diagnosing a Replacement FRU" in the Fujitsu M10-1/SPARC M10-1 Service Manual
"6.3 Diagnosing a Replacement FRU" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
11 Confirming that there is no problem with the replacement FRU "6.7 Checking the FRU Status After Maintenance" in the Fujitsu SPARC M12-1 Service Manual
"10.5.3 Checking the FRU Status After Maintenance" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.7 Checking the FRU Status after Maintenance" in the Fujitsu M10-1/SPARC M10-1 Service Manual
"6.3.3 Checking the FRU status after maintenance" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
12 Checking the firmware version and matching it with the pre-replacement one, if you have replaced an I/O board "6.6 Updating the Firmware of the PCI Expansion Unit"
13 Returning the mode switch on the operation panel to Locked mode "6.8 Returning the Mode Switch to Locked Mode" in the Fujitsu SPARC M12-1 Service Manual
"2.3.2 OPNL Control Function" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.8 Returning the Mode Switch to Locked Mode" in the Fujitsu M10-1/SPARC M10-1 Service Manual
"6.6 Returning the Mode Switch to Locked Mode" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
14 Starting the system "6.9 Starting the System" in the Fujitsu SPARC M12-1 Service Manual
"10.9 Starting the System" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.9 Starting the System" in the Fujitsu M10-1/SPARC M10-1 Service Manual
"6.8 Starting the Entire System" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
15 Closing the rack door  
Cold Replacement (Releasing the Link Card Using PHP)
Cold replacement can be performed for all the FRUs mounted on the PCI expansion unit after releasing the link card mounted on the destination server from the system using PCI hot plug (PHP). This can be done only when the connection destination of the PCI expansion unit is the SPARC M12-2/M12-2S/M10-4/M10-4S and the setting for the direct I/O function is disabled.
Figure 7-4  Cold Replacement Flow (Releasing the Link Card Using PHP)
Figure 7-4  Cold Replacement Flow (Releasing the Link Card Using PHP)
Table 7-6  Cold Replacement Work Procedure (Releasing the Link Card Using PHP)
Step Task Reference
1 Opening the rack door  
2 Locating the PCI expansion unit requiring maintenance by causing the CHECK LED (locator) of the unit to blink "5.2 Checking the PCI Expansion Unit Requiring Maintenance and the Destination Physical Partition"
3 Checking the firmware version of the PCI expansion unit, if you are replacing an I/O board "5.3 Checking the Firmware Version of the PCI Expansion Unit"
4 Checking the operating condition of the system and the I/O device usage status "5.4.1 Checking the Operating Condition of the Physical Partition or Logical Domain"
"5.4.2 Checking the Assignment Status of I/O Devices"
5 Releasing the link card mounted on the server from the system using PCI hot plug (PHP) "5.5.1 Releasing the Link Card or PCIe Card Using PCI Hot Plug (PHP)"
6 Enabling access to the FRU requiring maintenance "5.7 Accessing a FRU"
7 Replacing a faulty FRU "Chapter 8 Maintaining the PCI Express Cards"
"Chapter 9 Maintaining the Link Board"
"Chapter 11 Maintaining the Link Cables"
"Chapter 12 Maintaining the Management Cable"
"Chapter 13 Maintaining the Power Supply Units"
"Chapter 14 Maintaining the Fan Units"
"Chapter 15 Maintaining the PCI Tray"
"Chapter 16 Maintaining the I/O Board"
"Chapter 17 Maintaining the Fan Backplane"
8 Installing the front cover, if you have removed it "6.1.1 Installing the Front Cover"
9 Mounting the released link card on the system using PCI hot plug (PHP) "6.3.1 Mounting a Link Card Using PCI Hot Plug (PHP)"
10 Fixing the cable support "6.1.3 Fixing the Cable Support"
11 Confirming that there is no problem with the replacement FRU "10.5.3 Checking the FRU Status After Maintenance" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.3.3 Checking the FRU status after maintenance" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
12 Closing the rack door  
Cold Replacement (Releasing the Link Card Using DR)
Cold maintenance can be performed for all the FRUs mounted on the PCI expansion unit after releasing the chassis in which the link card is mounted from the system using physical partition dynamic reconfiguration (DR). This can be done only when the connection destination of the PCI expansion unit has the building block configuration of the SPARC M12-2S/M10-4S.
Figure 7-5  Cold Replacement Flow (Releasing the Link Card Using DR)
Figure 7-5  Cold Replacement Flow (Releasing the Link Card Using DR)
Table 7-7  Cold Replacement Work Procedure (Releasing the Link Card Using DR)
Step Task Reference
1 Opening the rack door  
2 Locating the PCI expansion unit requiring maintenance by causing the CHECK LED (locator) of the unit to blink "5.2 Checking the PCI Expansion Unit Requiring Maintenance and the Destination Physical Partition"
3 Checking the firmware version of the PCI expansion unit, if you are replacing an I/O board "5.3 Checking the Firmware Version of the PCI Expansion Unit"
4 Checking the operating condition of the system and the I/O device usage status "5.4 Checking the Operating Condition and Resource Usage Status"
5 Releasing the link card mounted on the server from the system using physical partition dynamic reconfiguration (DR) "5.5.2 Releasing the Link Card or PCIe Card Using Physical Partition Dynamic Reconfiguration (DR)"
6 Enabling access to the FRU requiring maintenance "5.7 Accessing a FRU"
7 Replacing a faulty FRU "Chapter 8 Maintaining the PCI Express Cards"
"Chapter 9 Maintaining the Link Board"
"Chapter 11 Maintaining the Link Cables"
"Chapter 12 Maintaining the Management Cable"
"Chapter 13 Maintaining the Power Supply Units"
"Chapter 14 Maintaining the Fan Units"
"Chapter 15 Maintaining the PCI Tray"
"Chapter 16 Maintaining the I/O Board"
"Chapter 17 Maintaining the Fan Backplane"
8 Restoring the PCI expansion unit "6.1 Restoring the Chassis of the PCI Expansion Unit"
9 Mounting the released link card on the system using physical partition dynamic reconfiguration (DR) "6.3.2 Mounting the Link Card on the Server Using Physical Partition Dynamic Reconfiguration (DR)"
10 Confirming that there is no problem with the replacement FRU "10.5.3 Checking the FRU Status After Maintenance" in the Fujitsu SPARC M12-2/M12-2S Service Manual
"6.3.3 Checking the FRU status after maintenance" in the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual
11 Closing the rack door