5.2 Checking the PCI Expansion Unit Requiring Maintenance and the Destination Physical Partition


5.2 Checking the PCI Expansion Unit Requiring Maintenance and the Destination Physical Partition
This section checks the PCI expansion unit requiring maintenance and the physical partition to which the PCI expansion unit belongs.
  1. Log in to the XSCF shell.
  2. Execute the ioxadm locator command to cause the CHECK LED of the PCI expansion unit requiring maintenance to blink so that you can locate the unit.
    You do not have to perform this step when performing maintenance on the link card mounted on a server.
    In the following example, the CHECK LED of PCIBOX#2007 is specified.
XSCF> ioxadm locator on PCIBOX#2007
  1. For the building block configuration of the SPARC M10-4S, execute the ioxadm list command to check the BB-ID of the server that is connected to the PCI expansion unit requiring maintenance.
    The following example shows that the BB-ID is "BB#01."
XSCF> ioxadm list PCIBOX#2007
PCIBOX Link
PCIBOX#2007 BB#01-PCI#05
  1. For the building block configuration of the SPARC M12-2S/M10-4S, execute the showboards -a command to check the PPAR-ID of the physical partition using the link card.
    The BB-ID of the server to which the PCI expansion unit requiring maintenance is connected is displayed as a system board (PSB) number.
    In the following example, the [PPAR-ID] of PSB 01-0 is "01."
XSCF> showboards -a
PSB PPAR-ID(LSB) Assignment Pwr Conn Conf Test Fault
---- ------------ ----------- ---- ---- ---- ------- --------

00-0 00(00) Assigned y y y Passed Normal
01-0 00(01) Assigned y y y Passed Normal