4.1.3 Locating the PCI Expansion Unit Requiring Maintenance


4.1.3 Locating the PCI Expansion Unit Requiring Maintenance
This section describes the procedure for locating a PCI expansion unit requiring maintenance by causing the CHECK LED (locator) on the front panel of the chassis to blink.
To locate the PCI expansion unit requiring maintenance, execute the ioxadm command of the XSCF firmware to cause the CHECK LED for the expansion unit to blink. For details on the location of the CHECK LED and the procedure for checking it, see "2.2.1 Front LEDs on the PCI Expansion Unit."
  1. Log in to the XSCF shell.
  2. Execute the ioxadm command to cause the CHECK LED of the PCI expansion unit requiring maintenance to blink to locate it.
    In the following example, the CHECK LED of PCIBOX#2008 is specified.
XSCF> ioxadm locator on PCIBOX#2008
Location Sensor Value Resolution Units
PCIBOX#2008 LOCATE Blink - LED
PCIBOX#2008/FAN#0 SERVICE Blink - LED