8.6 Installing the XSCF Unit


8.6 Installing the XSCF Unit
This section describes the procedure for installing the XSCF unit.
Caution - When mounting an XSCF unit, check the connectors on both the chassis and XSCF unit beforehand to confirm that no pin is bent and all the pins are neatly arranged in lines. If an XSCF unit is mounted with a bent pin in a connector, the chassis or XSCF unit may be damaged. Also, carefully proceed with the work to prevent any pin from being bent.
  1. Carefully insert the XSCF unit into the chassis.
  2. Raise the right and left levers and tighten the two screws.
  3. Reconnect all the cables to the XSCF unit.
    The cables to be reconnected are as follows.
    Serial cable

    LAN cable
Note - Reinstall the cables in their original positions by referring to the notes that you made prior to the start of maintenance.
The FRU installation work is completed. See "Chapter 7 Maintenance Flow" to continue maintenance work.