Skip to main content

6.3.2 Checking the FRU Status After Maintenance


6.3.2 Checking the FRU Status After Maintenance
This section describes the procedure for confirming that the FRU is operating normally after the completion of maintenance.
  1. Log in to the XSCF shell.
  2. Execute the showstatus command.
    If there is no problem, nothing is displayed.
XSCF> showstatus
  1. Execute the showlogs error command.
    Confirm that no new errors are displayed.
XSCF> showlogs error
  1. Execute the showhardconf command.
    Confirm that no asterisk (*) is displayed in front of any FRU.
    The following example shows execution on the SPARC M10-4S.
XSCF> showhardconf
SPARC M10-4S;
+ Serial:2081229003; Operator_Panel_Switch:Service;
+ System_Power:On; System_Phase:Cabinet Power On;
Partition#0 PPAR_Status:Running;
BB#00 Status:Normal; Role:Master; Ver:2050h; Serial:2081229003;
+ FRU-Part-Number:CA07361-D202 A0 ;
+ Power_Supply_System: ;
+ Memory_Size:320 GB;
------------------------Omitted------------------------

PCI#0 Status:Normal; Name_Property:pci;
+ Vendor-ID:108e; Device-ID:9020;
+ Subsystem_Vendor-ID:0000; Subsystem-ID:0000;
+ Model:;
+ Connection:7001;
PCIBOX#7001; Status:Faulted; Ver:1110h; Serial:2121237001;
+ FRU-Part-Number:;
IOB Status:Normal; Serial:PP123403JE ;
+ FRU-Part-Number:CA20365-B66X 008AG ;
LINKBOARD Status:Normal; Serial:PP1234026P ;
+ FRU-Part-Number:CA20365-B60X 001AA ;
PCI#1 Name_Property:ethernet;
+ Vendor-ID:1077; Device-ID:8000;
+ Subsystem_Vendor-ID:1077; Subsystem-ID:017e;
+ Model:;
------------------------Omitted---------------------