20.3.2 For the SPARC M10-4S
20.3.2 For the SPARC M10-4S
- Remove all the power cords of the SPARC M10-4S and crossbar box from the PDU requiring maintenance.
- Remove the four PDU screws.
|
- Grasp the top and bottom of the PDU, and pull it out.
|
- Remove all the power cords from the rear of the PDU.
Note - Hold the plug of a power cord, and pull the plug straight out. |
|
- The number of power cords and the plug type may vary depending on the power environment, as follows:- For a single-phase power feed:
Four power cords are connected to the PDU. To pull them out, push the upper and lower latches (A in Figure 20-12).
|
- - For a three-phase power feed:
Three power cords are connected to the PDU. To pull them out, turn the ring (A in Figure 20-13) counterclockwise.
|