Skip to main content

20.3.2 For the SPARC M10-4S


20.3.2 For the SPARC M10-4S
  1. Remove all the power cords of the SPARC M10-4S and crossbar box from the PDU requiring maintenance.
  2. Remove the four PDU screws.
Figure 20-9  PDU Screws
Figure 20-9  PDU Screws
  1. Grasp the top and bottom of the PDU, and pull it out.
Figure 20-10  Pulling Out the PDU
Figure 20-10  Pulling Out the PDU
  1. Remove all the power cords from the rear of the PDU.
Note - Hold the plug of a power cord, and pull the plug straight out.
Figure 20-11  Power Cord of the PDU
Figure 20-11  Power Cord of the PDU
  1. The number of power cords and the plug type may vary depending on the power environment, as follows:
    - For a single-phase power feed:
    Four power cords are connected to the PDU. To pull them out, push the upper and lower latches (A in Figure 20-12).
Figure 20-12  Power Cord Connector for Single-Phase Power Feed
Figure 20-12  Power Cord Connector for Single-Phase Power Feed
  1. - For a three-phase power feed:
    Three power cords are connected to the PDU. To pull them out, turn the ring (A in Figure 20-13) counterclockwise.
Figure 20-13  Power Cord Connector for Three-Phase Power Feed
Figure 20-13  Power Cord Connector for Three-Phase Power Feed