2.3.3 LEDs on Each Component
2.3.3 LEDs on Each Component
Each component of the crossbar box has an LED mounted. If a component experiences an error, check the LEDs to see which component requires maintenance. Check the LEDs before starting maintenance work.
The LEDs on each component and the states that they indicate are as follows.
The LEDs on each component and the states that they indicate are as follows.
|
Location Number | Name | Color | State | Description |
---|---|---|---|---|
1 | READY | Green | On | The XSCF is running. |
Blinking | The XSCF is being started. | |||
Off | The XSCF is stopped. | |||
2 | CHECK | Amber | On | An error has occurred. |
Blinking | The component requires maintenance. (This function is also referred to as the locator.) |
|||
Off | Normal state | |||
3 | MASTER | Green | On | Master chassis |
Off | Slave chassis |
Location No. | Name | Color | State | Description |
---|---|---|---|---|
4 | ACT | Green | Blinking | Communication is being performed. |
Off | Communication is not being performed. | |||
5 | LINK SPEED | Amber | On | The communication speed is 1 Gbps. |
Green | On | The communication speed is 100 Mbps. | ||
Off | The communication speed is 10 Mbps. |
|
Name | Color | State | Description |
---|---|---|---|
CHECK | Amber | On | An error has occurred. |
Blinking | The component requires maintenance. (This function is also referred to as the locator.) |
||
Off | Normal state |
|
Name | Color | State | Description |
---|---|---|---|
CHECK | Green | On | The input power is turned on and being supplied normally. |
Blinking | The input power is being disconnected. | ||
Amber | On | An error has occurred. The input power to this power supply unit has been turned off during redundant operation. |
|
Blinking | Warning status (An error has occurred but the power supply unit is operating.) | ||
Off | Power is not being supplied. |
< Previous Page | Next Page >