8.4 Removing the XSCF Unit


8.4 Removing the XSCF Unit
This section describes the procedure for removing the XSCF unit.
Enable the removal of the XSCF unit before attempting to remove it. For details, see "Chapter 7 Maintenance Flow."
Caution - Before you handle any components, wear a wrist strap to ground any static electricity. If you perform this procedure without a wrist strap, individual components or the overall system may be damaged. For details, see "1.4 Notes Regarding Static Electricity."
  1. Remove all the cables connected to the maintenance-target XSCF unit.
    The cables to be removed are as follows.
    Serial cable

    LAN cable
Note - Record the positions of the cables before removing them to ensure that they are reinstalled correctly.
  1. Loosen the two screws (A in Figure 8-2) of the XSCF unit and lower the right and left levers to release the XSCF unit.
Figure 8-2  Positions of Screws and Levers
Figure 8-2  Positions of Screws and Levers
  1. Hold the levers and partially pull out the XSCF unit.
Figure 8-3  Pulling Out the XSCF Unit
Figure 8-3  Pulling Out the XSCF Unit
  1. Support the XSCF unit from below with one hand and remove it carefully.
Note - Place the removed XSCF unit on a grounded antistatic ESD mat.