3.4 System-Stopped Maintenance


3.4 System-Stopped Maintenance
The type of maintenance performed with all the physical partitions on the system stopped is referred to as system-stopped maintenance. There are two types of maintenance work for system-stopped/cold maintenance, as follows.
  1. Maintenance using the maintenance menu when only the SPARC M12-2S/M10-4S connecting to the crossbar box with cables to be replaced is in the cold state
  2. Maintenance without using the maintenance menu when all the crossbar boxes and the SPARC M12-2S/M10-4S are in the cold state
Table 3-3, Figure 3-5, Figure 3-6, and Figure 3-7 show FRUs of the crossbar box with system-stopped maintenance enabled.
Table 3-3  FRUs for Which System-Stopped Maintenance (Replacement) is Enabled
-: Maintenance cannot be performed.
FRU System-Stopped/Hot Maintenance System-Stopped/Cold Maintenance
XSCF unit OK (*1) OK (*1, *4, *6)
XSCF BB control cable OK (*2) OK (*5)
XSCF DUAL control cable OK OK (*6)
Crossbar cable - OK (*5)
Crossbar unit - OK (*6)
Power supply unit OK (*3) OK (*6)
XSCF interface unit - OK (*6)
Fan unit OK OK (*6)
Fan backplane - OK (*6)
Operation panel - OK (*6)
Cable kit - OK (*6)
Crossbar backplane unit - OK (*6)
Dedicated power distribution unit OK (*3) OK (*6)
*1 Maintenance is performed on the XSCF in the standby state or a slave XSCF. If the XSCF is operating as the master XSCF, switch it to a standby XSCF.
*2 Hot maintenance is enabled only when you perform maintenance work on an XSCF BB control cable connecting crossbar boxes to each other.
*3 This is supported only for a redundant configuration.
*4 When replacing the microSD card at the same time as the XSCF unit of a crossbar box in a SPARC M10 system, replace them during system-stopped/hot maintenance.
*5 To maintain the XSCF BB control cable and crossbar cable that connect the crossbar box to the chassis of the physical partition, the connected chassis must be powered off.
*6 Replacement is available only when all the chassis in the building block configuration are powered off.
Figure 3-5  System-Stopped/Hot Maintenance
Figure 3-5  System-Stopped/Hot Maintenance
Figure 3-6  System-Stopped/Cold Maintenance
Figure 3-6  System-Stopped/Cold Maintenance
Figure 3-7  System-Stopped/Cold Maintenance (All Power-off)
Figure 3-7  System-Stopped/Cold Maintenance (All Power-off)