7.4 System-Stopped Maintenance Flow


7.4 System-Stopped Maintenance Flow
This section describes the replacement workflows in the system-stopped state for FRUs mounted on the crossbar box.
Not only hot maintenance but also cold maintenance is available in the system-stopped state. Stop all the physical partitions and disconnect the power cords of all the chassis to perform system-stopped/cold maintenance for the following FRUs.
  1. XSCF unit
  2. XSCF DUAL control cable
  3. Crossbar unit
  4. Power supply unit
  5. XSCF interface unit
  6. Fan unit
  7. Fan backplane
  8. Operation panel
  9. Cable kit
  10. Crossbar backplane unit
  11. Dedicated power distribution unit

It is possible to replace the following FRUs with system-stopped/cold maintenance by stopping all the physical partitions and disconnecting the power cords of all the chassis. It is also possible to replace them by disconnecting only the power cord of the chassis of the SPARC M12-2S/M10-4S with the cable requiring maintenance connected.
The replacement procedure is the same as the replacement procedure in the inactive/cold state. For the replacement workflow and work procedure, see "7.3 Inactive Maintenance Flow."
  1. XSCF BB control cable
  2. Crossbar cable