6.2.2 Restoring the FRUs of the Chassis of the Physical Partition


6.2.2 Restoring the FRUs of the Chassis of the Physical Partition
This section describes the procedure for restoring the FRUs of the physical partition, using the operation for restoring the physical partition chassis to the building block configuration as an example.
Following the operations up to step 8 in "5.4.2 Releasing FRUs in the Chassis of the Physical Partition," the restoration procedure in the example below starts after the repair of the fault location and the completion of steps up to physical connection of the XSCF BB control cable, crossbar cables, etc.
  1. After installing the FRU requiring maintenance to the physical partition, return to the operation of the replacefru command of the XSCF firmware, and enter "f".
    In the following example, the connection of the power cord to the physical partition chassis and the start of blinking of the READY LED on the XSCF are confirmed, and "f" is entered.
Please execute the following steps:
1) Confirm the XSCF STANDBY LED of BB#0 is not lit.
2) Turn off the breaker of BB#0.
3) Remove BB#0.
4) Execute either the following:
4-1) After the exchanged device is connected with the system,
turn on the breaker of BB#0, and please select 'finish'.
4-2) If you want to suspend the maintenance without exchanging device,
please select 'cancel'.
[f:finish|c:cancel] :f
  1. Entering "f" displays the following screen. Wait until the processing has completed.
Waiting for BB#0 to enter install state.
[This operation may take up to 20 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90..... 120..... 150..... 180..... 210.....
240..... 270..... 300..... 330..... 360..... done

Waiting for BB#0 to enter ready state.
[This operation may take up to 45 minute(s)]
(progress scale reported in seconds)
0..... 30..... 60..... 90..... 120..... 150..... 180..... 210.....
240..... 270..... 300..... done
  1. When the chassis of the physical partition is incorporated, the following confirmation message appears. Enter "s".
Do you want to start to diagnose BB#0?[s:start|c:cancel] :s
  1. The following confirmation message appears. Enter "y" to start the diagnosis.
Diagnostic tests for BB#0 have started.
Initial diagnosis is about to start, Continue?[y|n] :y
  1. A screen like the one below appears. Wait until the processing has completed.
PSB#00-0 power on sequence started.
0..... 30..... 60..... 90.....120.....150.....180.....210.end
Initial diagnosis started. [7200sec]
0..... 30..... 60..... 90.....120.....150.....180.....210.....240.....|
270.....300.....330.....360.....390.....420.....450.....480.....510.....|

540.....570.....600.....630.....660.....690.....720.....750.....780.....\

810.....840.....870.....900.....930.end

Initial diagnosis has completed.
PSB power off sequence started. [1200sec]
0..... 30..... 60..... 90.end
PSB powered off.
PSB Test Fault
---- ------- --------

00-0 Passed Normal
done
  1. The diagnosis result appears when the diagnosis completes. Confirm that the status is normal ("Normal"), and then enter "f".
------------------------------------------------------------------------------

Maintenance/Replacement Menu
Status of the replaced FRU.

FRU Status
------------------- --------------

/BB#0 Normal
------------------------------------------------------------------------------

The replacement of BB#0 has completed normally.[f:finish] :f
  1. Enter "c" to stop maintenance, and terminate the replacefru command.
------------------------------------------------------------------------------

Maintenance/Replacement Menu
Please select a type of model which has FRU to be replaced.

1. BB (4s Building Block Model)

2. XBBOX (XB-BOX Model)

------------------------------------------------------------------------------

Select [1,2|c:cancel] :c