  9. 6.7 Checking the FRU Status After Maintenance

6.7 Checking the FRU Status After Maintenance


6.7 Checking the FRU Status After Maintenance
This section describes the procedure for confirming that the FRU is operating normally after the completion of maintenance.
  1. Log in to the XSCF shell.
  2. Execute the showstatus command.
    Nothing is displayed in the normal state.
XSCF> showstatus
  1. Execute the showlogs error command.
    Confirm that no new errors are displayed.
XSCF> showlogs error
  1. Execute the showhardconf command.
    Confirm that no asterisk (*) is displayed in front of any FRU.
XSCF> showhardconf
SPARC M12-1;
+ Serial:TZ41702002; Operator_Panel_Switch:Service;
+ System_Power:Off; System_Phase:Cabinet Power Off;
Partition#0 PPAR_Status:Powered Off;
MBU Status:Normal; Ver:900eh; Serial:TZ1701D01A ;
+ FRU-Part-Number:CA08208-D001 A0 /9999999 ;
+ Power_Supply_System: ;
+ Memory_Size:64 GB; Type: C ;
CPU#0 Status:Normal; Ver:4242h; Serial:00070390;
+ Freq:3.200 GHz; Type:0x30;
+ Core:6; Strand:8;
MEM#00A Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-1221E918;
+ Type:83; Size:16 GB;
MEM#01A Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-1221E8E3;
+ Type:83; Size:16 GB;
MEM#02A Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-1221E917;
+ Type:83; Size:16 GB;