  1. Confirm that the XSCF STANDBY LED on the operation panel is on.
  2. Log in to the XSCF shell.
  3. Execute the poweron command.
    Enter "y" in response to the confirmation message.
XSCF> poweron -a
PPAR-IDs to power on:00
Continue? [y|n] :y
00 : Powering on
  1. Confirm that the POWER LED on the operation panel is on.
  2. Execute the showpparstatus command to confirm that the power to the physical partition is turned on.
XSCF> showpparstatus -p 0
PPAR-ID PPAR Status
00    Running
  1. Execute the fmadm faulty command on the logical domains where an error is detected to confirm that no errors remain.
# fmadm faulty
  1. If any error remains, execute the fmadm repaired command to clear the error.