Skip to main content

4.1.3 Confirming FRU Information


4.1.3 Confirming FRU Information
FRU information includes detailed information on hardware. Log in to the XSCF shell and confirm FRU information when arranging for additional or replacement hardware, such as for hardware configuration changes or replacement of faulty hardware.
The examples in this section show commands for checking FRU information. For details on each command, see the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 XSCF Reference Manual of the XCP firmware version used.
Checking the number of mounted FRUs
XSCF> showhardconf -u
SPARC M12-1; Memory_Size:128 GB; (*1)
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| MBU | 1 |
| Type:G | ( 1) |
| CPU | 1 |
| Freq:3.200 GHz; | ( 1) |
| MEM | 8 |
| Type:83; Size:16 GB; | ( 8) |
| PCICARD | 0 |
| LINKCARD | 0 |
| PCIBOX | 0 |
| IOB | 0 |
| LINKBOARD | 0 |
| PCI | 0 |
| FANBP | 0 |
| PSU | 0 |
| FAN | 0 |
| OPNL | 1 |
| Type:A | ( 1) |
| PSUBP | 1 |
| Type:A | ( 1) |
| PSU | 2 |
| Type:B | ( 2) |
| FANU | 7 |
| HDDBP | 1 |
+-----------------------------------+------------+
XSCF>
*1 System model information and total capacity of mounted memory
Checking the FRU type
XSCF> showhardconf
SPARC M12-1;
(Omitted)
MBU Status:Normal; Ver:4016h; Serial:TZ2238D00B ;
+ FRU-Part-Number:CA08208-D041 A0 /8214923 ;
+ Power_Supply_System: ;
+ Memory_Size:128 GB; Type: G ;
CPU#0 Status:Normal; Ver:4242h; Serial:00189870;
+ Freq:3.200 GHz; Type:0x30;
+ Core:6; Strand:8;
MEM#00A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC 00-31C056F2;
+ Type:83; Size:16 GB;
(Omitted)
XSCF>
Table 4-2 lists combinations of the SPARC M12-1 (Fujitsu Product ID SPNAAAAxxx) and MBU types.

Table 4-2  Combinations of Servers and MBU Types
Server Fujitsu Product ID (Oracle Product ID) MBU Type Indicator
SPARC M12-1 SPNAAAA1xx (7118228), SPNAAAA2xx (7602945) C
  SPNAAAA3xx (7605161) F
  SPNAAAA4xx (7605940) G
Table 4-3 shows the correspondence between memory mounted in the SPARC M12-1 and FRU types.
Table 4-3  Correspondence Between Memory and Types
FRU Type Indicator Configuration
Memory 81 DDR4 R-DIMM 8 GB 1 Rank
  83 DDR4 R-DIMM 16 GB 1 Rank
  85 DDR4 R-DIMM 32 GB 2 Rank
  87 DDR4 R-DIMM 64 GB 4 Rank
  91 DDR4 R-DIMM 64 GB 2 Rank
Note - The FRU type indicator may vary depending on the hardware configuration.
See the information about the hardware in the Fujitsu SPARC M12 Product Notes for the latest XCP version.