Execute the showhardconf command to confirm the configuration and status of the FRU mounted in the SPARC M12-1. Before performing any maintenance work, be sure check and record the hardware configuration.
  1. Log in to the XSCF shell.
  2. Execute the showhardconf command to confirm the hardware configuration information.
The following information appears:
  1. Current configuration and status
  2. Number of mounted Field Replaceable Units (FRUs)
  3. Status of the unit in which a physical partition error or degradation occurred
  4. Information on the PCI expansion unit
  5. Name property of the PCIe card
The following is an example of executing the showhardconf command.
XSCF> showhardconf
SPARC M12-1;
+ Serial:TZ41702002; Operator_Panel_Switch:Service;
+ System_Power:Off; System_Phase:Cabinet Power Off;
Partition#0 PPAR_Status:Powered Off;
MBU Status:Normal; Ver:900eh; Serial:TZ1701D01A ;
+ FRU-Part-Number:CA08208-D001 A0 /9999999 ;
+ Power_Supply_System: ;
+ Memory_Size:64 GB; Type: C ;
CPU#0 Status:Normal; Ver:4242h; Serial:00070390;
+ Freq:3.200 GHz; Type:0x30;
+ Core:6; Strand:8;
MEM#00A Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-1221E918;
+ Type:83; Size:16 GB;
MEM#01A Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-1221E8E3;
+ Type:83; Size:16 GB;
MEM#02A Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-1221E917;
+ Type:83; Size:16 GB;
MEM#03A Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-1221E8E1;
+ Type:83; Size:16 GB;