4.1.1 Confirming the Hardware Configuration
4.1.1 Confirming the Hardware Configuration
Execute the showhardconf command to confirm the configuration and status of the FRU mounted in the SPARC M12-1. Before performing any maintenance work, be sure check and record the hardware configuration.
- Log in to the XSCF shell.
- Execute the showhardconf command to confirm the hardware configuration information.
The following information appears:
- Current configuration and status
- Number of mounted Field Replaceable Units (FRUs)
- Status of the unit in which a physical partition error or degradation occurred
- Information on the PCI expansion unit
- Name property of the PCIe card
The following is an example of executing the showhardconf command.
XSCF> showhardconf SPARC M12-1; + Serial:TZ41702002; Operator_Panel_Switch:Service; + System_Power:Off; System_Phase:Cabinet Power Off; Partition#0 PPAR_Status:Powered Off; MBU Status:Normal; Ver:900eh; Serial:TZ1701D01A ; + FRU-Part-Number:CA08208-D001 A0 /9999999 ; + Power_Supply_System: ; + Memory_Size:64 GB; Type: C ; CPU#0 Status:Normal; Ver:4242h; Serial:00070390; + Freq:3.200 GHz; Type:0x30; + Core:6; Strand:8; MEM#00A Status:Normal; + Code:2c800f18ASF2G72PZ-2G3B1 31-1221E918; + Type:83; Size:16 GB; MEM#01A Status:Normal; + Code:2c800f18ASF2G72PZ-2G3B1 31-1221E8E3; + Type:83; Size:16 GB; MEM#02A Status:Normal; + Code:2c800f18ASF2G72PZ-2G3B1 31-1221E917; + Type:83; Size:16 GB; MEM#03A Status:Normal; + Code:2c800f18ASF2G72PZ-2G3B1 31-1221E8E1; + Type:83; Size:16 GB; |