  9. 6.3.3 When the System is Configured With a Hardware RAID

6.3.3 When the System is Configured With a Hardware RAID


6.3.3 When the System is Configured With a Hardware RAID
If you have replaced the MBU in a hardware RAID configuration, activate the RAID volume.
  1. Log in to the XSCF shell.
  2. Execute the setpparparam command to suppress auto-boot.
XSCF> setpparparam -p 0 -s bootscript "setenv auto-boot false"
  1. Start the system.
    For details, see "6.9 Starting the System."
  2. The ok prompt appears.
  3. Enable the RAID volume to check the status.
    For details, see "14.2.11 Re-enabling a Hardware RAID Volume" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 System Operation and Administration Guide.
  4. Stop the system after returning the Auto boot setting to the original one.
{0} ok setenv auto-boot? true
XSCF> poweroff -a