6.3.3 When the System is Configured With a Hardware RAID
6.3.3 When the System is Configured With a Hardware RAID
If you have replaced the MBU in a hardware RAID configuration, activate the RAID volume.
- Log in to the XSCF shell.
- Execute the setpparparam command to suppress auto-boot.
XSCF> setpparparam -p 0 -s bootscript "setenv auto-boot false" |
- Start the system.
For details, see "6.9 Starting the System." - The ok prompt appears.
- Enable the RAID volume to check the status.
For details, see "14.2.11 Re-enabling a Hardware RAID Volume" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 System Operation and Administration Guide. - Stop the system after returning the Auto boot setting to the original one.
{0} ok setenv auto-boot? true XSCF> poweroff -a |
< Previous Page | Next Page >