2.4.1 Operation Panel LEDs
2.4.1 Operation Panel LEDs
The three LEDs on the operation panel indicate the operation status of the entire system. In addition, the LEDs enable you to check the system status by their combination of being on, blinking, or off. For the locations of the LEDs, see Figure 2-8.
Table 2-6 lists the system operation status indicated by the LEDs, while Table 2-7 lists the system status indicated by the combination of LEDs.
Table 2-6 lists the system operation status indicated by the LEDs, while Table 2-7 lists the system status indicated by the combination of LEDs.
Icon | Name | Color | State | Description |
---|---|---|---|---|
POWER | Green | On | The system is running. | |
Blinking | The system is being stopped. | |||
- | Off | The system is stopped. | ||
XSCF STANDBY |
Green | On | The XSCF is functioning normally. | |
Blinking | The XSCF is being initialized. | |||
- | Off | The XSCF is stopped. | ||
CHECK | Amber | On | Hardware has detected an error. | |
Blinking | The SPARC M12-1 specified at execution of the XSCF command instructing the blinking. This (locator) is used to identify the location of the SPARC M12-1 requiring maintenance. | |||
- | Off | Normal state, or the power is disconnected or otherwise not being supplied. |
LED State | Description | ||
---|---|---|---|
POWER | XSCF STANDBY |
CHECK | |
Off | Off | Off | The power is disconnected. |
Off | Off | On | The XSCF has detected an error before system start or after system stop. |
Off | Blinking | Off | The XSCF is being initialized. |
Off | On | Off | The XSCF is in the standby state. Or the system is waiting for power-on of the air conditioning facilities (in the data center). |
On | On | Off | Warm-up standby processing is in progress. After the end of this processing, the system starts up. Or the system startup processing is in progress. Or the system is in operation. |
On | On | On | Although the system is operating normally, an error has been detected. |
Blinking | On | Off | System stop processing is in progress. After the end of processing, the fan unit stops. |