10.4.1 Installing the HDDBP
This section describes the procedure for installing the HDDBP.
  1. Install the HDDBP by aligning the notches on both sides.
Figure 10-6  HDDBP Notches
Figure 10-6  HDDBP Notches
  1. Align the HDDBP with hooks on the chassis (three places) and push the HDDBP into place.
Figure 10-7  Hooks on the Chassis
Figure 10-7  Hooks on the Chassis
  1. Tighten the two screws of the HDDBP.
  1. Connect the two cables from the OPNL to the MBU.
Note - Connect the cables in their original positions by referring to the record that you made before the start of maintenance.
Note - When connecting the cables, insert them firmly. If there is a loose connection, the MBU will be unable to access the OPNL, resulting in an XSCF startup error.
Figure 10-8  OPNL Cables
Figure 10-8  OPNL Cables
  1. Store the connected cables in the cable guide, and lock the guide.
    For details, see "6.1.1 Locking the Cable Guide."
    If the cable guide does not have a lock, proceed to step 6.
  1. Connect the three cables to the HDDBP.
Note - Connect the cables in their original positions by referring to the record that you made before the start of maintenance.
Note - Connect the SAS cable with the metal part facing up.
Figure 10-9  HDDBP Cables
Figure 10-9  HDDBP Cables