13.4.1 Installing the Cable Kit


13.4.1 Installing the Cable Kit
  1. Lift the PSUBP, and connect the four cables (A in Figure 13-7) to the PSUBP.
Figure 13-7  PSUBP Cables
Figure 13-7  PSUBP Cables
  1. Install the PSUBP.
  2. Confirm that the two fixing pins are inserted into the PSUBP, and then slide the PSUBP toward the front of the SPARC M12-1.
  3. Tighten the one screw of the PSUBP.
  1. Connect the one cable that connects the PSUBP to the HDDBP.
Figure 13-8  HDDBP Cable
Figure 13-8  HDDBP Cable
  1. Store the connected cables in the cable guide, and lock the guide.
    For details, see "6.1.1 Locking the Cable Guide."
  1. Connect the three cables that connect the PSUBP to the MBU.
Note - Connect the cables in their original positions by referring to the record that you made before the start of maintenance.
Note - Make sure that each cable is firmly inserted.
Figure 13-9  MBU Cables
Figure 13-9  MBU Cables