3.3 System-Stopped Maintenance (Inactive Maintenance)
3.3 System-Stopped Maintenance (Inactive Maintenance)
The type of maintenance performed with the physical partition stopped is referred to as system-stopped maintenance (inactive maintenance). The SPARC M12-1 has only one physical partition. Thus, the state in which the physical partition requiring maintenance is stopped is the same as the state in which the entire system is stopped.
Table 3-3 shows whether system-stopped maintenance (inactive maintenance) is enabled for each FRU.
-: Maintenance cannot be performed. |
|||
---|---|---|---|
FRU | System-Stopped (Inactive)/ Hot Maintenance |
System-Stopped (Inactive)/ Cold Maintenance |
Reference |
PCIe card | - (*1) |
OK | Chapter 8 |
HDD/SSD | OK | OK | Chapter 9 |
HDDBP | - | OK | Chapter 10 |
PSU | OK (*2) | OK | Chapter 11 |
PSUBP | - | OK | Chapter 12 |
Cable kit | - | OK | Chapter 13 |
OPNL | - | OK | Chapter 14 |
FANU | OK | OK | Chapter 15 |
MBU | - | OK | Chapter 16 |
Memory | - | OK | Chapter 16 |
*1 System-stopped (inactive)/hot maintenance can be performed on the PCIe cards mounted in the PCI expansion unit. For details, see "3.3 Types of Maintenance for the PCIe Card" in the PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual. *2 If the XSCF startup mode is high-speed mode, hardware cannot be replaced using the replacefru command. Perform system-stopped (inactive)/cold maintenance. |
< Previous Page | Next Page >