3.3 System-Stopped Maintenance (Inactive Maintenance)


3.3 System-Stopped Maintenance (Inactive Maintenance)
The type of maintenance performed with the physical partition stopped is referred to as system-stopped maintenance (inactive maintenance). The SPARC M12-1 has only one physical partition. Thus, the state in which the physical partition requiring maintenance is stopped is the same as the state in which the entire system is stopped.
Table 3-3 shows whether system-stopped maintenance (inactive maintenance) is enabled for each FRU.
Table 3-3  Whether System-Stopped Maintenance (Inactive Maintenance) (Replacement/Addition/Removal) is Enabled for Each FRU
-: Maintenance cannot be performed.
FRU System-Stopped (Inactive)/
Hot Maintenance
System-Stopped (Inactive)/
Cold Maintenance
Reference
PCIe card
- (*1)
OK Chapter 8
HDD/SSD OK OK Chapter 9
HDDBP - OK Chapter 10
PSU OK (*2) OK Chapter 11
PSUBP - OK Chapter 12
Cable kit - OK Chapter 13
OPNL - OK Chapter 14
FANU OK OK Chapter 15
MBU - OK Chapter 16
Memory - OK Chapter 16
*1 System-stopped (inactive)/hot maintenance can be performed on the PCIe cards mounted in the PCI expansion unit. For details, see "3.3 Types of Maintenance for the PCIe Card" in the PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual.
*2 If the XSCF startup mode is high-speed mode, hardware cannot be replaced using the replacefru command. Perform system-stopped (inactive)/cold maintenance.