16.6.3 Restoring the Server
16.6.3 Restoring the Server
- Install the air duct and the PSUBP cover.
For details, see "6.1.2 Installing the Air Duct and PSUBP Cover." - Install the upper cover.
For details, see "6.1.3 Installing the Upper Cover." - Close the fan cover.
For details, see "6.1.4 Closing the Fan Cover." - Put the SPARC M12-1 into the rack.
For details, see "6.1.5 Putting the SPARC M12-1 Into the Rack." - Connect all the cables of the external interface.
Note - Reinstall the cables in their original positions by referring to the record that you made before the start of maintenance. |
- Disconnect the XSCF LAN cables, and connect the serial cable.
- Connect the power cords of the SPARC M12-1 requiring maintenance at their original positions.
Note - Reinstall the power cords in their original positions by referring to the record that you made before the start of maintenance. |
Note - The XSCF STANDBY LED (green) on the operation panel blinks when the power cords are connected. As the LED blinks, wait a moment for it to stay on. This indicates that XSCF initialization completed successfully. |
- Log in to the XSCF via the serial port.
- Set the XSCF time.
For details on the procedure, see "6.3.1 Setting the Time." - Confirm that the XSCF reboots, and then connect the XSCF LAN cable.
Note - Reinstall the cables in their original positions by referring to the record that you made before the start of maintenance. |
- Match the XCP firmware version with the pre-replacement version.
For details on the procedure, see "6.3.2 Confirming the Firmware Version."
The FRU installation work is completed. See "Chapter 7 Maintenance Flow" to continue maintenance work.