6.9.2 Starting the system from the operation panel
6.9.2 Starting the system from the operation panel
- Check that the XSCF STANDBY LED on the operation panel is on.
- Press the power switch on the operation panel for 1 second or more (less than 4 seconds).
For details, see "2.3.2 Control function of the operation panel." - Confirm that the POWER LED on the operation panel is on.
- Log in to the XSCF shell.
- Execute the showpparstatus command to confirm that the power to the physical partition is turned on.
XSCF> showpparstatus -p 0 PPAR-ID PPAR Status 00 Running |
- Execute the fmadm faulty command on the logical domains where an error is detected to confirm that no errors remain.
# fmadm faulty |
- If any error remains, execute the fmadm repaired command to clear the error.