2.3.2 Control function of the operation panel


2.3.2 Control function of the operation panel
The operation panel has the following switches to implement its control function:
  1. Mode switch (slide switch)
    Specifies the operation or maintenance mode.
  2. Power switch
    Controls start/stop of the system.
Figure 2-9  Operation panel switches
Figure 2-9  Operation panel switches
Location number Switch
1 Mode switch
2 Power switch
The mode switch sets the operation mode for the system. The Locked and Service operation modes can be switched by sliding the mode switch.
Table 2-3 describes the difference between the modes.
Table 2-3  Functions of the mode switch
Icon Name Description
locked_mode Locked mode Mode used for normal operation
- The power switch can be used to start the system but not to stop it.
service_mode Service mode Mode used for maintenance
- The power switch cannot be used to start the system but can be used to stop it.

- Place the system in Service mode to perform maintenance work with the system stopped.
Use the power switch to start or stop the system. The system starts/stops differently depending on how the power switch is pressed.
Table 2-4 describes how system starts/stops vary depending on how the power switch is pressed.
Table 2-4  Functions of the power switch
Icon Operation Description  
power switch Brief press
(For 1 second or more and less than 4 seconds)
If the system has been started in Service mode: Operation is ignored.
If the system is stopped in Service mode: Operation is ignored.
If the system has been started in Locked mode: Operation is ignored.
If the system is stopped in Locked mode: Starts the system.
At this time, if a wait time for the air conditioning facilities or a warm-up time is set on the XSCF, the processing for waiting for the power-on of the air conditioning facilities and the completion of warm-up is omitted.
Long press
(For 4 seconds or more)
If the system has been started in Service mode: Perform the system shutdown process to stop the system.
If the system startup process is in progress in Service mode: Cancels the system startup process and stops the system.
If the system stop process is in progress in Service mode: Continues the system stop process.
If the system is stopped in Service mode: Operation is ignored.
Even a long press does not start the system.
If the system is stopped in Locked mode: Starts the system.
If a wait time for the air conditioning facilities or a warm-up time is set on the XSCF, the processing for waiting for the power-on of the air conditioning facilities and the completion of warm-up is omitted.
If the system is not stopped in Locked mode: Operation is ignored.
Table 2-5 describes the functions of the mode switch.
Table 2-5  Functions of the mode switch
Function Mode switch
Locked Service
Start/stop of the system by the power switch Only system startup is enabled. A long press powers off the system.
Inhibition of break signal reception Enabled. Using the setpparmode command, you can specify whether to receive break signals or inhibit their reception for each physical partition. Disabled