Skip to main content
  1. Home >
  2. Products >
  3. Computing Products >
  4. Servers >
  5. Fujitsu SPARC servers >
  6. Downloads >
  7. User Manuals >
  8. Fujitsu M10-1/SPARC M10-1 Service Manual >
  9. 3.1 Types of Maintenance Supported in the SPARC M10-1

3.1 Types of Maintenance Supported in the SPARC M10-1


3.1 Types of Maintenance Supported in the SPARC M10-1
The types of maintenance supported in the SPARC M10-1 depend on the system operation status during maintenance. The supported maintenance is divided into two types: active maintenance and system-stopped (inactive) maintenance.
  1. Active maintenance
    Type of maintenance performed while Oracle Solaris is operating
  2. System-stopped maintenance (inactive maintenance)
    Type of maintenance performed with the physical partition stopped
    SPARC M10-1 has the only one physical partition. Thus, the state in which the physical partition requiring maintenance is stopped is the same as the state in which the entire system is stopped.
Each of the above two maintenance types is further divided into the two types of hot maintenance and cold maintenance.
  1. Hot maintenance
    Type of maintenance performed with the power cords connected to the chassis requiring maintenance
  2. Cold maintenance
    Type of maintenance performed with the power cords removed from the chassis requiring maintenance