Fujitsu M10-1/SPARC M10-1 Service Manual
>
Chapter 15 Maintaining the Fan Units
Contents
Preface
Chapter 1 Before Starting Maintenance Work
1.1 Warning/Caution Indications
1.2 Labels/Tags
1.3 Safety Precautions
1.4 Precautions on Static Electricity
1.5 Other Precautions
1.6 Emergency Power Off
Chapter 2 Understanding the System Components
2.1 Identifying the Names and Locations of Components
2.2 Checking the Memory Configuration Rules
2.2.1 Memory installation rules
2.2.2 Checking memory information
2.3 Confirming the Functions of the Operation Panel
2.3.1 Display function of the operation panel
2.3.2 Control function of the operation panel
2.4 Checking the LED Indications
2.4.1 Operation panel LEDs
2.4.2 LEDs on the rear panel (System locator)
2.4.3 LEDs on each component
Chapter 3 Types of Maintenance
3.1 Types of Maintenance Supported in the SPARC
M10-1
3.2 Active Maintenance
3.3 System-stopped Maintenance (Inactive Maintenance)
Chapter 4 Preparation and Precautions for Maintenance
4.1 Confirming the System Configuration
4.1.1 Confirming the hardware configuration
4.1.2 Confirming the software and firmware configurations
4.1.3 Confirming the FRU information and resource information
4.2 Troubleshooting
4.2.1 Confirming whether there is a failure
4.2.2 Identifying a failure
4.2.3 Downloading error log information
4.3 Maintenance Precautions
4.3.1 Precautions for replacement
4.3.2 Precautions for expansion
4.3.3 Precautions for reduction
Chapter 5 Preparations Required for Maintenance
5.1 Preparing Tools Required for Maintenance
5.2 Switching the Mode Switch to Service Mode
5.3 Checking the Operating Condition and Resource Usage Status
5.3.1 Checking the operating condition of the physical partition or logical domain
5.3.2 Checking the assignment status of I/O devices
5.3.3 Checking the usage status of the internal disk
5.4 Enabling the Removal of an Internal Disk
5.4.1 How to identify a disk slot
5.4.2 Releasing an internal disk from the system
5.5 Stopping the Entire System
5.5.1 Stopping the system with the XSCF command
5.5.2 Stopping the system from the operation panel
5.6 Saving Setting Information and Configuration Information
5.6.1 Saving XSCF setting information
5.6.2 Setting recovery mode
5.6.3 Saving the logical domain configuration information and OpenBoot PROM environment variables
5.7 Releasing a FRU from the System with the replacefru Command
5.8 Accessing a FRU
5.8.1 Removing the power cords
5.8.2 Removing the cables
5.8.3 Pulling the chassis out from the rack
5.8.4 Opening the fan cover
5.8.5 Removing the upper cover
5.8.6 Removing the air duct and PSU backplane cover
5.8.7 Releasing the cable guide lock
Chapter 6 Understanding the Preparations for Restoring the System
6.1 Restoring the Chassis
6.1.1 Locking the cable guide
6.1.2 Installing the air duct and PSU backplane cover
6.1.3 Installing the upper cover
6.1.4 Closing the fan cover
6.1.5 Putting the chassis into the rack
6.1.6 Installing the power cords
6.2 Incorporating a FRU into the System with the replacefru Command
6.3 After Replacing the Motherboard Unit/PSU Backplane
6.3.1 Setting the time
6.3.2 Confirming the firmware version
6.3.3 When the system is configured with a hardware RAID
6.4 Diagnosing a Replacement FRU
6.5 Restoring Setting Information and Configuration Information
6.5.1 Restoring XSCF setting information
6.5.2 Confirming that the logical domain configuration is the same as that before memory was installed
6.5.3 Restoring the logical domain configuration information and OpenBoot PROM environment variables
6.6 Incorporating an Internal Disk
6.7 Checking the FRU Status after Maintenance
6.8 Returning the Mode Switch to Locked Mode
6.9 Starting the System
6.9.1 Starting the system with an XSCF command
6.9.2 Starting the system from the operation panel
Chapter 7 Maintenance Flow
7.1 Maintenance Workflow
7.2 FRU Replacement Workflow
7.2.1 Active replacement
7.2.2 System-stopped replacement
7.3 FRU Installation Workflow
7.3.1 Active addition
7.3.2 System-stopped addition
7.4 FRU Removal Workflow
7.4.1 Active removal
7.4.2 System-stopped removal
Chapter 8 Maintaining the PCI Express Cards
8.1 Before Maintaining a PCI Express Card
8.2 PCI Express Card Configuration
8.3 Removing a PCI Express Card
8.3.1 Accessing a PCIe card
8.3.2 Removing a PCI Express riser
8.3.3 Removing a PCIe card
8.4 Installing a PCI Express Card
8.4.1 Installing a PCI Express card
8.4.2 Installing a PCIe riser
8.4.3 Restoring the chassis
Chapter 9 Maintaining the Internal Disks
9.1 Before Maintaining an Internal Disk
9.2 Configuration of the Internal Disks
9.3 Removing an Internal Disk
9.4 Installing an Internal Disk
Chapter 10 Maintaining the HDD Backplane
10.1 Before Maintaining the HDD Backplane
10.2 HDD Backplane Location
10.3 Removing the HDD Backplane
10.3.1 Accessing the HDD backplane
10.3.2 Removing the HDD backplane
10.4 Installing the HDD Backplane
10.4.1 Installing the HDD backplane
10.4.2 Restoring the chassis
Chapter 11 Maintaining the Power Supply Units
11.1 Before Maintaining a Power Supply Unit
11.2 Configuration of the Power Supply Units
11.3 Removing a Power Supply Unit
11.3.1 Accessing a power supply unit
11.3.2 Removing a power supply unit
11.4 Installing a Power Supply Unit
11.4.1 Installing a power supply unit
11.4.2 Restoring the chassis
Chapter 12 Maintaining the PSU Backplane
12.1 Before Maintaining the PSU Backplane
12.2 PSU Backplane Location
12.3 Precautions for Maintaining the PSU Backplane
12.4 Removing the PSU Backplane
12.4.1 Accessing the PSU backplane
12.4.2 Removing the PSU backplane
12.5 Installing the PSU Backplane
12.5.1 Installing the PSU backplane
12.5.2 Restoring the chassis
Chapter 13 Maintaining the Cable Kit
13.1 Before Maintaining the Cable Kit
13.2 Cable Kit Location
13.3 Removing the Cable Kit
13.3.1 Accessing the cable kit
13.3.2 Removing the cable kit
13.4 Installing the Cable Kit
13.4.1 Installing the cable kit
13.4.2 Restoring the chassis
Chapter 14 Maintaining the Operation Panel
14.1 Before Maintaining the Operation Panel
14.2 Operation Panel Location
14.3 Removing the Operation Panel
14.3.1 Accessing the operation panel
14.3.2 Removing the operation panel
14.4 Installing the Operation Panel
14.4.1 Installing the operation panel
14.4.2 Restoring the chassis
Chapter 15 Maintaining the Fan Units
15.1 Before Maintaining a Fan Unit
15.2 Configuration of the Fan Units
15.3 Removing a Fan Unit
15.3.1 Accessing a fan unit
15.3.2 Removing a fan unit
15.4 Installing a Fan Unit
15.4.1 Installing a fan unit
15.4.2 Restoring the chassis
Chapter 16 Maintaining the Motherboard Unit/Memory
16.1 Before Maintaining the Motherboard Unit/Memory
16.2 Motherboard Unit Location
16.3 Memory Locations
16.4 Precautions for Motherboard Unit Replacement
16.5 Removing the Motherboard Unit and Memory
16.5.1 Accessing the motherboard unit
16.5.2 Removing memory
16.5.3 Removing the motherboard unit
16.5.4 Switching the microSD card
16.6 Installing the Motherboard Unit and Memory
16.6.1 Installing the motherboard unit
16.6.2 Installing memory
16.6.3 Restoring the chassis
Appendix A Component List
Appendix B Component Specifications
B.1 Motherboard Unit
B.2 Power Supply Unit
B.3 Fan Unit
B.4 Internal Disk
B.5 PCI Express Card
B.6 Backplanes
B.7 Operation Panel
Appendix C Oracle Solaris Troubleshooting Commands
C.1 iostat Command
C.2 prtdiag Command
C.3 prtconf Command
C.4 netstat Command
C.5 ping Command
C.6 ps Command
C.7 prstat Command
Appendix D External Interface Specifications
D.1 Serial Port
D.1.1 Wire connection chart for serial cables
D.2 USB Port
D.3 SAS Port
D.4 RESET Switch
Appendix E Removing the Lithium Battery
E.1 Location of the Lithium Battery
E.2 Removing the Lithium Battery
Table of contents
Glossary
Word index
Chapter 15 Maintaining the Fan Units
Chapter 15 Maintaining the Fan Units
This chapter describes the maintenance procedure for the fan units.
Before Maintaining a Fan Unit
Configuration of the Fan Units
Removing a fan unit
Installing a fan unit
<
Previous Page
|
Next Page
>
Top of Page