Skip to main content
  1. Home >
  2. Products >
  3. Computing Products >
  4. Servers >
  5. Fujitsu SPARC servers >
  6. Downloads >
  7. User Manuals >
  8. Fujitsu M10-1/SPARC M10-1 Service Manual >
  9. 6.2 Incorporating a FRU into the System with the replacefru Command

6.2 Incorporating a FRU into the System with the replacefru Command


6.2 Incorporating a FRU into the System with the replacefru Command
This section describes the procedure for incorporating a Field Replaceable Unit (FRU) into the system after maintenance. To do this, resume the replacefru command, which is running, to incorporate the FRU into the system. The following FRUs can be maintained.
  1. Power supply unit
  2. Fan unit
  1. After performing maintenance on the FRU, return to the operation of the XSCF firmware replacefru command, and then enter "f".
Please execute the following steps:
1) Confirm the Check LED is blinking.
2) Remove FAN#6.
3) Execute either the following:
3-1) After installing the exchanged device, please select 'finish'.
3-2) If you want to suspend the maintenance without exchanging device,
please select 'cancel'.
[f:finish|c:cancel] :f
  1. The following screen is displayed. Wait until the processing has completed.
Waiting for FAN#6 to enter install state.
[This operation may take up to 1 minute(s)]
(progress scale reported in seconds)
0.. done

Diagnostic tests for FAN#6 have started.
[This operation may take up to 6 minute(s) 30 second(s)]
(progress scale reported in seconds)
0.... 30..... 60..... 90. done
  1. If your XSCF firmware version is earlier than XCP 2220, the underlined part is displayed as "4 minute(s)."
  1. Confirm that the status is normal ("Normal") after diagnosis, and then enter "f".
------------------------------------------------------------------------------

Maintenance/Replacement Menu
Status of the replaced FRU.

FRU Status
------------------- --------------

/FAN#6 Normal
------------------------------------------------------------------------------

The replacement of FAN#6 has completed normally.[f:finish] :f
  1. When the maintenance menu appears, enter "c" to exit the operation.
------------------------------------------------------------------------------

Maintenance/Replacement Menu
Please select a type of model which has FRU to be replaced.

1. FAN (Fan Unit)

2. PSU (Power Supply Unit)

------------------------------------------------------------------------------

Select [1,2|c:cancel] :c