Skip to main content
  1. Home >
  2. Products >
  3. Computing Products >
  4. Servers >
  5. Fujitsu SPARC servers >
  6. Downloads >
  7. User Manuals >
  8. Fujitsu M10-1/SPARC M10-1 Service Manual >
  9. 5.7 Releasing a FRU from the System with the replacefru Command

5.7 Releasing a FRU from the System with the replacefru Command


5.7 Releasing a FRU from the System with the replacefru Command
This section describes the procedure for releasing a FRU requiring maintenance from the system. The following FRUs can be maintained.
  1. Power supply unit
  2. Fan unit
Note - If the XSCF startup mode is high-speed mode, hardware cannot be replaced using the replacefru command. Replace hardware with the input power turned off.
  1. Log in to the XSCF shell.
  2. Execute the replacefru command to display the maintenance menu.
XSCF> replacefru
  1. Select the FRU requiring maintenance by specifying it with a numeric key.
    In the following example, since the fan unit is selected, "1" is entered.
------------------------------------------------------------------------------

Maintenance/Replacement Menu
Please select a type of model which has FRU to be replaced.

1. FAN (Fan Unit)

2. PSU (Power Supply Unit)

------------------------------------------------------------------------------

Select [1,2|c:cancel] :1
  1. Select the FRU requiring maintenance by specifying it with a numeric key.
    In the following example, since FAN#6 is showing "Faulted" indicating an error, "7" is entered.
------------------------------------------------------------------------------

Maintenance/Replacement Menu
Please select a FRU to be replaced.

No. FRU Status
--- ------------------- --------------

1 /FAN#0 Normal
2 /FAN#1 Normal
3 /FAN#2 Normal
4 /FAN#3 Normal
5 /FAN#4 Normal
6 /FAN#5 Normal
7 /FAN#6 Faulted
------------------------------------------------------------------------------

Select [1-7|b:back] :7
  1. After confirming that the selected FRU is displayed, enter [r].
You are about to replace FAN#6.
Do you want to continue?[r:replace|c:cancel] : r
  1. Confirm that the CHECK LED of the FRU is blinking.
    For the CHECK LED location, see "2.4.3 LEDs on each component."
Please execute the following steps:
1) Confirm the Check LED is blinking.
2) Remove FAN#6.
3) Execute either the following:
3-1) After installing the exchanged device, please select 'finish'.
3-2) If you want to suspend the maintenance without exchanging device,
please select 'cancel'.
[f:finish|c:cancel] :
You can now start FRU maintenance. Do not enter "f" until you complete the maintenance work.
After replacing the FRU, perform the work in "6.2 Incorporating a FRU into the System with the replacefru Command" to incorporate the FRU into the system.