Problems Resolved in XCP 2362
Problems Resolved in XCP 2362
The following table lists the problems resolved in XCP 2362.
RTI No. | RTIF2-200805-002 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | Security fixes. (CVE-2019-11477, CVE-2019-11478, CVE-2019-11479) For details, see the Oracle website relating to the following: Critical Patch Updates |
Workaround | Update the XCP firmware to XCP 2362 or later. |
RTI No. | RTIF2-200528-004 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | Wrong PCI INTx interrupt control may cause logical domains to panic. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-200518-002 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | When a snapshot is collected with USB memory specified as log save destination, collection will end normally but without a log collected in the snapshot. The problem when this USB memory is specified as the data save destination also occurs with the following XSCF commands or XSCF Web operations: - dumpconfig, dumpcodactivation, getremotepwrmgmt, or showcodactivationhistory command - Configuration Backup/Restore on the [Maintenance] - [Configuration Management] menu - CoD Activation History on the [Settings] - [CoD Activation] menu |
Workaround | Check the collected file size in the USB memory. If the size is 0, collect data by executing the XSCF command or XSCF Web operation again. |
RTI No. | RTIF2-200518-004 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | Suppose an XSCF user account managed with the Lightweight Directory Access Protocol (LDAP), Active Directory, and the LDAP over SSL service is used to log in to XSCF Web. If the user account name contains a period ".", login fails with the following message displayed. System Error! Unknown system error,please contact the administrator. |
Workaround | There is no effective workaround. |