Problems Resolved in XCP 2270
Problems Resolved in XCP 2270
The following table lists the problems resolved in XCP 2270.
RTI No. | RTIF2-201118-004 |
Model | SPARC M10-4, SPARC M10-4S |
Description | In a system with a connected PCI expansion unit, "SCF process down detected" may be registered in the error log when the XCP firmware is updated. |
Workaround | There is no effective workaround. [How to restore] Perform the following procedure. 1. Execute the showlogs command. 2. If the displayed error log is the same as shown below, power off the input power supply and then power it on again. [Example] XSCF> showlogs error -V Date: Jul 04 16:05:56 JST 2014 Code: 20000000-00fcff0056010000ff-010400010000000000000000 Status: Notice Occurred: Jul 04 16:05:56.951 JST 2014 FRU: /FIRMWARE,/BB#0/CMUL Msg: SCF process down detected Diagnostic Code: 00000000 00000000 0000 00000000 00000000 0000 00000000 00000000 0000 6462696e 69745f6d 632exxxx xxxxxxxx 00000000 00000000 0000 You can check it by confirming that [Msg:] is "SCF process down detected" and the first 10 bytes on the 4th line of [Diagnostic Code:] have the value "6462696e 69745f6d 632e". |
RTI No. | RTIF2-160129-003 |
Model | SPARC M10-4S |
Description | Suppose that a total of 47 or more PCI cards or link cards is installed in one physical partition (PPAR) and that "Msg: SB deconfigured (not running)" is registered in the error log when the PPAR is powered on. Then, the PPAR may be powered on with a degraded PSB. |
Workaround | There is no effective workaround. Perform the following procedure. 1. Set the mode switch on the operation panel (OPNL) of the master chassis to Service. 2. Turn off the input power to the system and then turn it on again (AC OFF/ON). 3. Reset the mode switch on the OPNL of the master chassis. 4. Power on the PPAR. |
< Previous Page | Next Page >