Problems Resolved in XCP 2322
The following table lists the problems resolved in XCP 2322.
Table 3-25  Problems Resolved in XCP 2322
RTI No. RTIF2-161013-001
Model SPARC M10-1, SPARC M10-4, SPARC M10-4S
Description If IP addresses are set to both XSCF-LAN#0 and XSCF-LAN#1, the XSCF-LAN#1 IP address may be set as the Agent Address for the SNMP Trap of SNMPv1.
Therefore, a retry by resource management software (ServerView Resource Orchestrator) to switch the servers may fail.
This symptom occurs when no takeover IP address is set for the SPARC M10-4S.
Workaround There is no effective workaround.
RTI No. RTIF2-161004-001
Model SPARC M10-1, SPARC M10-4, SPARC M10-4S
Description The OID information of scfPPARStatus (PPAR status information) in the definition file of the XSCF extension MIB is not updated even when the control domain is rebooted.
Therefore, a retry by resource management software (ServerView Resource Orchestrator) to switch the servers may fail.
Workaround There is no effective workaround.
RTI No. RTIF2-161004-002
Model SPARC M10-1, SPARC M10-4, SPARC M10-4S
Description If you mount an IHV graphics card on a PCI Express expansion unit from IHV and connect the PCI Express expansion unit to the SPARC M10, the error "IOC register compare error" may be detected.
Workaround Set the POST diagnosis level to "off".
Perform the following.
1. Power off the physical partition.
XSCF> poweroff -p x

2. Set the POST diagnosis level to "off".
XSCF> setpparmode -p x -m diag=off