Problems Resolved in XCP 2050
Problems Resolved in XCP 2050
The following table lists the problems resolved in XCP 2050.
RTI No. | RTIF2-210209-007 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | If the XSCF reboots while Oracle Solaris is running, you may be unable to connect to the control domain console by executing the console command after the XSCF reboot. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-201109-023 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | A logical domain might panic with BAD TRAP due to a logical domain channel (LDC) under heavy load. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-201109-024 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | A logical domain might panic when the ldm remove-memory command is executed dynamically for it. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-201109-026 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | Hypervisor might abort if the console paths change while the PPAR is starting up. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-131107-002 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | If the input power to the system is turned on, the XSCF is reset, or the XCP firmware is updated, the "SCF Diagnosis initialize RTC" error is erroneously detected, causing the following phenomena to occur. - Symptom 1 The XSCF time may return to January 1, 1970. - Symptom 2 The time difference between the XSCF and all physical partitions (PPARs) may become a value of 1.3 billion seconds or more. You can check this phenomenon by executing the showdateoffset(8) command, since the time difference between the XSCF and all the PPARs is displayed as a value of "1300000000 sec" or more. XSCF> showdateoffset -a PPAR-ID Domain Date Offset 00 1300000100 sec 01 1300000100 sec : : 15 1300000100 sec - Symptom 3 When you reset the PPAR or power cycle the PPAR, the Oracle Solaris time may return to January 1, 1970. |
Workaround | There is no effective workaround. Update to firmware version XCP 2050 or later. [How to restore] See "Restoration After Erroneous Detection of the "SCF Diagnosis initialize RTC" Error (RTIF2-131107-002)." |
RTI No. | RTIF2-131023-005 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | If the [Physical] bar is selected on the XSCF Web menu, PCI (excluding the link card) may appear to be abnormal ( ). |
Workaround | There is no effective workaround. Even if PCI (excluding the link card) is indicated as being abnormal ( ), ignore it. |
RTI No. | RTIF2-130903-005 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | In the XSCF e-mail notification function, the following characters cannot be included in the local part or the domain part of the reply mail address which is sent by the setsmtp(8) command. "!" "#" "$" "%" "&" "'" "*" "+" "/" "=" "?" "^" "_" "`" "{" "|" "}" "~" |
Workaround | Use reply mail addresses which do not include the characters shown by the description. |
RTI No. | RTIF2-130528-001 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | You cannot use the PCI hot plug (PHP) function to add a Quad Gigabit Ethernet card (SE1X7GQ2F) to a PCI Express slot of a PCI expansion unit. |
Workaround | This has been modified with XCP 2050 and SRU 11.1.6.4.0. If XCP and SRU are not applied, you must stop the logical domain to which you want to add the PCI card before adding it. [Precautions] To resolve this problem when you have saved the configuration information of the logical domain and are operating the system with a configuration other than factory-default, you must reconstruct the logical domain configuration after update of the XCP firmware. For details, see "Reconstructing the Logical Domain (RTIF2-130528-001)." |
RTI No. | RTIF2-130516-003 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | If the XSCF load is high, the following warning message may be output, indicating the power supply unit (PSU) as a suspected location. Insufficient FAN rotation speed PSU voltage out of range error PSU output current too high PSU over temperature warning |
Workaround | There is no workaround. This is a warning message, so you can operate it as it is. Ignore the message. |
RTI No. | RTIF2-130329-004 |
Model | SPARC M10-4S |
Description | In a system with building block configuration, if the following operations are performed during power-on of the physical partition (PPAR), connection to the control domain console may not be possible. 1. The XSCF for any of the SPARC M10-4S units composing the PPAR is reset. 2. The master XSCF and standby XSCF are switched. 3. The XSCF of the SPARC M10-4S that was reset in 1. is reset again. |
Workaround | There is no effective workaround. Reset the master XSCF using the switchscf(8) command. |
RTI No. | RTIF2-130329-006 |
Model | SPARC M10-4S |
Description | If the XSCF of the SPARC M10-4S belonging to the physical partition (PPAR) in operation is rebooted due to a panic or watchdog timeout while the master XSCF and the standby XSCF are restarting simultaneously, connection to the control domain console may not be possible. |
Workaround | There is no effective workaround. Power off the PPAR by using the poweroff -f command, and then power it on again. |
RTI No. | RTIF2-130319-002 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | Before power-off of the physical partition (PPAR) completes in a SPARC M10-4S, suppose you cycle the input power to the SPARC M10-4S or a crossbar box and power on the PPAR again. Then, the PPAR in operation may be powered off if the master XSCF is switched with the switchscf(8) command, firmware update, or failure. |
Workaround | If you power off the PPAR before powering off the input power supply of the SPARC M10-4S or crossbar box, check that power-off of the target PPAR and SPARC M10-4S is complete, by using the showboards(8) and showlogs power commands. Then, power off the input power supply of the SPARC M10-4S or crossbar box. |
RTI No. | RTIF2-130319-003 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | If the shutdown -i5 command and power-off command compete for power-off of the PPAR when the former is executed in the control domain or the latter is executed from the ok prompt while power-off of the physical partition (PPAR) is performed with the poweroff(8) command, "SCF:PPAR issued power-off request (PPARID X)" may be registered many times. |
Workaround | Ignore the registered event log, because the PPAR has been normally powered off. |
RTI No. | RTIF2-130305-016 |
Model | SPARC M10-4S |
Description | Timeout may occur if the XCP firmware version of a SPARC M10-4S or crossbar box is updated using the flashupdate -c sync command. |
Workaround | Execute the flashupdate(8) command by specifying the -f option to re-update the XCP firmware for all SPARC M10-4S or crossbar boxes. |
RTI No. | RTIF2-130219-002 |
Model | SPARC M10-4S |
Description | When maintaining SPARC M10-4S with a slave XSCF, if you incorrectly connect the standby XSCF and the slave XSCF with an XSCF connection cable, the maintenance is considered to have finished normally without detecting the error. |
Workaround | After switching between the master XSCF and the standby XSCF by using the switchscf(8) command, execute the testsb(8) command to the target slave XSCF. The incorrect connection with the XSCF connection cable is detected and an error log is issued. |
Reconstructing the Logical Domain (RTIF2-130528-001)
To resolve this problem when you have saved the configuration information of the logical domain and are operating the system with a configuration other than factory-default, you must reconstruct the logical domain configuration after update of the XCP firmware through the following procedure:
- Check the current configuration information of the logical domain stored on the XSCF.This example assumes that the name of the saved logical domain configuration information is config1.
XSCF> showdomainconfig -p 0 20xx-yy-zz hh:mm:ss PPAR-ID :0 Booting config (Current) :config1 (Next) :config1 -------------------------------------------------------------- Index :1 config_name :factory-default domains :1 date_created:- -------------------------------------------------------------- Index :2 config_name :config1 domains :2 date_created:'20xx-yy-zz hh:mm:ss' |
- Set a dummy variable and then clear it for all logical domains.
Execute the following commands for all logical domains.
primary# ldm set-variable fix-php=true ldom primary# ldm remove-variable fix-php ldom |
- Save the changed configuration to the XSCF to replace the current configuration information.
In this example, the name of the current configuration information is replaced with config1.
primary# ldm remove-spconfig config1 primary# ldm add-spconfig config1 |
- Restart all logical domains.
Restoration After Erroneous Detection of the "SCF Diagnosis initialize RTC" Error (RTIF2-131107-002)
[How to restore]
- If phenomenon 1 occurs: - Case 1If the Oracle Solaris time has returned to January 1, 1970, execute the setdate(8) command to set the XSCF time again. In this case, the XSCF is rebooted. After that, power cycle the PPAR. After this, the XSCF is reset. After that, power on the PPAR.- Case 2If the Oracle Solaris time is other than January 1, 1970, contact a field engineer. In this case, do not execute the resetdateoffset(8) of setdate(8) command on the XSCF.- Case 3If the PPAR power is off, power on the PPAR. After that, check the Oracle Solaris time, and perform the above case 1 or case 2.
- If phenomenon 2 occurs: - Case 1If the Oracle Solaris time has returned to January 1, 1970, it is necessary to initialize the time difference between the XSCF time and Hypervisor on all of the PPARs. Stop all the PPARs, and execute the resetdateoffset -a command to clear the time difference.- Case 2If the Oracle Solaris time is other than January 1, 1970, contact a field engineer. In this case, do not execute the resetdateoffset(8) of setdate(8) command on the XSCF.- Case 3If the PPAR power is off, power on the PPAR. After that, check the Oracle Solaris time, and perform the above case 1 or case 2.
- If phenomenon 3 occurs:
If phenomenon 1 or 2 also occurs, perform its [How to restore] action first.
Set the Oracle Solaris time again.
< Previous Page | Next Page >