RTI No. | RTIF2-201215-002 |
Model | SPARC M10-4S |
Description | If the threshold of the system caps for power consumption is exceeded during dynamic reconfiguration of a physical partition (PPAR DR), Oracle Solaris may inadvertently be shut down. |
Workaround | Before performing PPAR DR, execute the setpowercapping command to disable the power capping function. |
RTI No. | RTIF2-201117-003 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | While the OS console is in use, the execution of the console command to connect to the OS console may cause an unexpected message to appear before the login prompt. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-201116-001 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | In a system with a connected PCI expansion unit, an XSCF reboot may cause the "SCF process down detected" error in some very rare cases. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-201116-005 |
Model | SPARC M10-4S |
Description | In a system with a building block configuration, "XB-XB Interface Correctable Error" may inadvertently be registered in the error log in some very rare cases. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-201116-006 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | On a system with XCP 2330 and XCP 2332 applied, no connection over HTTPS can be made to XSCF Web when elliptic curve cryptography is used. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-201116-010 |
Model | SPARC M10-1 |
Description | If a failure occurs on the I/O board in a PCI expansion unit, "UNSPECIFIED" instead of the faulty component may be registered for the suspected location in the error log. [Example] XSCF> showlogs error -rvM Date: Mar 21 13:15:30 JST 2017 Code: 20000000-00c7010000ff0000ff-030000020000000000000000 Status: Notice Occurred: Mar 21 13:15:30.364 JST 2017 FRU: UNSPECIFIED Msg: Boot process failed |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-201116-011 |
Model | SPARC M10-4 |
Description | If a PCIe card failure occurs in the PCI expansion unit connected to PCI slot #9 in the SPARC M10-4, the registered suspected location in the error log does not show the number of the PCI expansion unit. [Example] FRU: /BB#1/PCI#9/PCIBOX#/PCI#1 |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-201110-004 |
Model | SPARC M10-4S |
Description | In a system with a building block configuration, the "XSCF hang-up is detected" error may be detected in some rare cases. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-201109-009 |
Model | SPARC M10-4S |
Description | Hypervisor abort might occur if live migration of a guest domain and PPAR DR are performed sequentially. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-171013-001 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | Security fixes. (CVE-2016-6304, CVE-2016-2182, CVE-2016-2183, CVE-2016-6302, CVE-2016-6306, CVE-2016-6515, CVE-2017-3731, CVE-2016-7431, CVE-2016-7429, CVE-2016-7433) For details, see the Oracle website relating to the following: Critical Patch Updates |
Workaround | Update the XCP firmware to XCP 2340 or later. |
RTI No. | RTIF2-170421-001 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | Booting from an external DVD drive may fail. [Example of output message] {0} ok boot /pci@8000/pci@4/pci@0/pci@2/pci@0/usb@4,1/cdrom@2/disk Boot device: /pci@8000/pci@4/pci@0/pci@2/pci@0/usb@4,1/cdrom@2/disk File and args: Can't open boot device |
Workaround | 1. Stop OpenBoot PROM at the ok prompt. 2. Perform the following steps to change the OpenBoot PROM environment variable nvramrc. a. Execute the nvedit command, and write nvramrc as shown below. {0} ok nvedit 0: : patch-zero 0 to my-adr0 0 ; 1: ' patch-zero ' 0 ' new-instance d# 28 + token@ (patch b. Press the [Ctrl] + [C] keys to exit nvedit and return to the ok prompt. c. Execute nvstore to save the edited contents. {0} ok nvstore d. Check whether nvramrc was written correctly. {0} ok printenv nvramrc nvramrc = : patch-zero 0 to my-adr0 0 ; ' patch-zero ' 0 ' new-instance d# 28 + token@ (patch {0} ok 3. Set the OpenBoot PROM environment variable use-nvramrc? to true. {0} ok setenv use-nvramrc? true use-nvramrc? = true 4. Execute the reset-all command to restart OpenBoot PROM. {0} ok reset-all After executing the reset-all command and the system stops at the ok prompt, boot from a DVD drive. Example: For booting from a DVD drive connected to a front USB port {0} ok boot /pci@8000/pci@4/pci@0/pci@2/pci@0/usb@4,1/cdrom@2/disk To restore the original settings from the above settings in [Workaround], perform the following steps. 1. Stop OpenBoot PROM at the ok prompt. 2. Delete the set values from the OpenBoot PROM environment variable nvramrc. a. Execute nvedit to delete ": patch-zero 0 to my-adr0 0 ;" and "' patch-zero ' 0 ' new-instance d# 28 + token@ (patch" from nvramrc. You can delete lines one by one by pressing the [Ctrl] + [K] keys twice at the beginning of a line. {0} ok nvedit 0: b. Press the [Ctrl] + [C] keys to exit nvedit and return to the ok prompt. c. Execute nvstore to save the edited contents. {0} ok nvstore d. Check whether the nvramrc setting was deleted correctly. {0} ok printenv nvramrc nvramrc = {0} ok 3. Set the OpenBoot PROM environment variable use-nvramrc? to false. If it was set to true before this workaround was performed, this step is unnecessary. {0} ok setenv use-nvramrc? false use-nvramrc? = false {0} ok 4. Execute the reset-all command to restart OpenBoot PROM. {0} ok reset-all |
RTI No. | RTIF2-170407-001 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | The ttydm process may fail and the following logs may be registered if you reboot the XSCF by executing the rebootxscf(8), switchscf(8), or flashupdate(8) command while console messages are continuously output from the control domain. [Example] XSCF> showlogs error -vr Date: Mar 02 22:23:00 JST 2015 Code: 20000000-00fcff000e020000ff-010400010000000000000000 Status: Notice Occurred: Mar 02 22:22:54.396 JST 2015 FRU: /FIRMWARE,/MBU Msg: SCF process down detected Diagnostic Code: 00000000 00000000 0000 00000000 00000000 0000 00000000 00000000 0000 74747964 6d2e3237 36342e62 7a320000 00000000 00000000 0000 You can check the ttydm process by confirming that the first four bytes on the fourth line of "Diagnostic Code" have the value "747479646d". |
Workaround | There is no effective workaround. Logs are collected. The XSCF is rebooted. |
RTI No. | RTIF2-170406-001 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | From XCP 2230 onwards, a process may produce a core dump if Dynamic Resource Management (DRM) of Oracle VM Server for SPARC is used or a virtual CPU is deleted by executing the ldm remove-vcpu command. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-170406-002 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | When you select the [XSCF] - [Logs] - [Console Log] menu from XSCF Web and display log information, the following error appears in a pop-up window and the screen returns to the login window. Description Server Internal error or the page you visit does not exist or has been deleted! Sorry for any inconvenience! |
Workaround | There is no effective workaround. Execute the showlogs command in the XSCF shell to check the console log. |
RTI No. | RTIF2-170405-004 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | If a security key is used for booting Oracle Solaris on the control domain and you save the domain configuration information by using the following procedure, the next boot fails. 1. Execute the set-security-key command or the set-ascii-security-key command at the ok prompt of OpenBoot PROM on the control domain to set a security key. 2. Save the domain configuration information to the XSCF by executing the ldm add-spconfig command of Oracle VM Server for SPARC. 3. Boot Oracle Solaris on the control domain. This problem does not occur on a guest domain. [Example] Booting Oracle Solaris fails after a security key is set SPARC M10-4S, No Keyboard Copyright (c) 1998, 2016, Oracle and/or its affiliates. All rights reserved. OpenBoot 4.38.5, 126.0000 GB memory available, Serial #*********. [ 2.21.0 ] Ethernet address **:**:**:**:**:**, Host ID: ********. -- Omitted -- Boot device: /pci@8000/pci@4/pci@0/pci@9/network@0 File and args: 100 Mbps full duplex Link up 100 Mbps full duplex Link up 100 Mbps full duplex Link up SunOS Release 5.11 Version 11.3 64-bit Copyright (c) 1983, 2015, Oracle and/or its affiliates. All rights reserved. NOTICE: Configuring iSCSI boot session... Hostname: solaris solaris console login: root Password: Last login: Wed Jan ** **:**:** 2017 on console Jan ** **:**:** solaris login: ROOT LOGIN /dev/console^M Oracle Corporation SunOS 5.11 11.3 September 2015 You have mail. root@solaris:~# ldm ls-spconfig factory-default [current] root@solaris:~# ldm add-spconfig ldm-cfg1 root@solaris:~# ldm ls-spconfig factory-default ldm-cfg1 [current] root@solaris:~# init 6 -- Omitted -- SPARC M10-4S, No Keyboard Copyright (c) 1998, 2016, Oracle and/or its affiliates. All rights reserved. OpenBoot 4.38.5, 126.0000 GB memory available, Serial #*********. [ 2.21.0 ] Ethernet address **:**:**:**:**:**, Host ID: ********. 100 Mbps full duplex Link up Boot device: net File and args: 100 Mbps full duplex Link up ERROR: /iscsi-hba: iSCSI login failed ERROR: /packages/obp-tftp: Could not open /iscsi-hba/disk Boot load failed Evaluating: {0} ok |
Workaround | There is no effective workaround. [How to restore] After executing the ldm add-spconfig command from Oracle VM Server for SPARC to store the domain configuration information in the XSCF, set the security key again by executing the set-ascii-security-key command or set-security-key command at the ok prompt of OpenBoot PROM. |
RTI No. | RTIF2-170405-006 |
Model | SPARC M10-4S |
Description | In a system with a building block configuration, the following error log may be registered when the input power is turned on (AC ON) or the rebootxscf -a command is used. XSCF data synchronization failed At this time, the physical partition cannot be powered on. |
Workaround | There is no effective workaround. Reboot all the XSCFs by using the rebootxscf -a command. |
RTI No. | RTIF2-170405-011 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | The showinterimpermit command cannot be executed with the fieldeng privilege. |
Workaround | Execute the command with any of the following user privileges. platadm, platop, pparadm, pparmgr, pparop |
RTI No. | RTIF2-170331-001 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | On a SPARC M10 system with SPARC64 X processors, Hypervisor may abort after performing a live migration on a guest domain. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-161215-001 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | If a live migration of a guest domain fails, logical domains on the physical partition as the migration source may panic or Hypervisor may abort. |
Workaround | There is no effective workaround. If a live migration fails, reboot the guest domain as soon as possible. |
RTI No. | RTIF2-161117-001 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | If you boot/reboot logical domains after the elapse of a certain period of time from physical partition (PPAR) power-on, the boot/reboot may fail. This problem occurs in a boot/reboot from an internal LAN. This problem happens during the time period described below. - The first period is the 15-minute period after the elapse of "24 days, 20 hours, 16 minutes, and 23.648 seconds" from physical partition (PPAR) power-on. Each subsequent period is the 15-minute period after the elapse of a multiple of time of "49 days, 17 hours, 02 minutes, and 47.296 seconds." (15-minute period on the 25th day and then the 75th day, 125th day, 175th day, and so on at an interval of approximately 50 days) [Example] Period of 15 minutes from 24th day, 20 hours, 16 minutes, and 23.648 seconds to (same day and hour) 31 minutes and 23.648 seconds Period of 15 minutes from 74th day, 13 hours, 19 minutes, and 10.944 seconds to (same day and hour) 34 minutes and 10.944 seconds [Example of failure] Oracle Solaris is booted from internal LAN in control domain on SPARC M10-4 SPARC M10-4S, No Keyboard Copyright (c) 1998, 2016, Oracle and/or its affiliates. All rights reserved. OpenBoot 4.38.5, xx.xxxx GB memory available, Serial #xxxxxxxx. [ 2.19.0 ] Ethernet address xx:xx:xx:xx:xx:xx, Host ID: xxxxxxxx. 1000 Mbps full duplex Link up Boot device: net:dhcp File and args: 1000 Mbps full duplex Link up Timed out waiting for BOOTP/DHCP reply Timed out waiting for BOOTP/DHCP reply Timed out waiting for BOOTP/DHCP reply Timed out waiting for BOOTP/DHCP reply Timed out waiting for BOOTP/DHCP reply Timed out waiting for BOOTP/DHCP reply : : |
Workaround | There is no effective workaround. [How to restore] Execute the sendbreak command from the XSCF. After the system stops at the ok prompt and 15 minutes elapse, execute the boot command. |
RTI No. | RTIF2-150226-002 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | CHECK LED of the old master XSCF blinks during the master/standby switchover of XSCFs. |
Workaround | There is no effective workaround. Ignore the blinking CHECK LED of the old master XSCF during the master/standby switchover of XSCFs. |
RTI No. | RTIF2-141008-001 |
Model | SPARC M10-1, SPARC M10-4, SPARC M10-4S |
Description | If the setsnmp command tries to set enabled immediately after disabled was set, the "Agent enable failed" message may appear, and the command may fail. This may cause the following phenomena. 1. If it is left as is, "SCF panic detected" is registered in the error log, and the XSCF is rebooted. 2. The setting is not reflected, so if the showsnmp command is executed, it displays "Enabled" for "Agent Status" and "None" for "Enabled MIB Modules." 3. If the showsnmp command is executed, it displays "Enabled" for "Agent Status" and "SP MIB" for "Enabled MIB Modules." However, the setting has not actually been reflected, so rebooting the XSCF causes "None" to be displayed for "Enabled MIB Modules." 4. The setting has not been reflected, so when the showsnmp command displays "None" for "Enabled MIB Modules," the system using the cluster software detects the following error: "FJSVcluster: Error: DEV: 7240: Cannot connect to the XSCF." [Example] After the setsnmp command fails, the setting is not reflected. XSCF> setsnmp disable XSCF> setsnmp enable setsnmp: Agent enable failed XSCF> showsnmp Agent Status: Enabled Agent Port: 161 System Location: System-Location System Contact: System-Contact : Status: Enabled Community String: public Enabled MIB Modules: None XSCF> Similarly, this problem also occurs when the setsnmpusm command or setsnmpvacm command is executed to change the setting while the SNMP setting is enabled. |
Workaround | To change the setting to enabled after it was changed to disabled, wait at least 30 seconds, the minimum interval. To change the setting with the setsnmpusm command or setsnmpvacm command, temporarily change the SNMP setting to disable, and then wait at least 30 seconds, the minimum interval. [How to restore] Temporarily set disable with the setsnmp command, and then wait at least 30 seconds, the minimum interval, to set enable. Next, execute the showsnmp, setsnmpusm, or showsnmpvacm command to confirm that the setting has been reflected as expected. |