Problems Resolved in XCP 2052
The following table lists the problems resolved in XCP 2052.
Table 3-47  Problems Resolved in XCP 2052
RTI No. RTIF2-210104-003
Model SPARC M10-4S
Description If a failure occurs in the crossbar unit (XBU), the registered suspected location in the error log may be wrong.
Workaround There is no effective workaround.
RTI No. RTIF2-201215-012
Model SPARC M10-4S
Description After initializing the setting information for an XSCF unit with the restoredefaults command, you might set the BB-ID of the SPARC M10 chassis to 00 or 01 and the BB-ID of the crossbar box to 80 or 81. Then, "BOARD ERROR" may be detected when the input power to the chassis alone is turned on.
Workaround There is no effective workaround.
RTI No. RTIF2-131004-004
Model SPARC M10-4S
Description If the standby XSCF is rebooted while the XSCF BB control cable is either faulty or not connected, it is started as the master XSCF, so that there are two master XSCF units in the system.
When there are two master XSCF units, system operation cannot be guaranteed.
This state can be confirmed from the fact that there are two chassis for which the MASTER LED is lit on their rear panels.
Workaround There is no effective workaround.
Do not reset an XSCF when the XSCF BB control cable between the master and standby is either faulty or not connected.
[How to restore]
If there are two master XSCF units in the system, turn off all the chassis and then turn them on again.
RTI No. RTIF2-130903-004
Model SPARC M10-4S
Description If XSCF master/standby switchover takes place when either the XSCF BB control cable or the XSCF DUAL control cable is not connected properly, the settings on the master XSCF side may not be properly carried on to the standby XSCF and thus, it may not operate properly.
Workaround There is no effective workaround.
Please make sure that the XSCF BB control cable and the XSCF DUAL control cable is properly connected.
If this symptom occurs, check whether each setting by the master XSCF had been stored after confirming that the cables are properly connected. Set up XSCF again when the setting has not been saved.
RTI No. RTIF2-130827-001
Model SPARC M10-1, SPARC M10-4, SPARC M10-4S
Description A timeout or connection failure may be detected for the communication party because XSCF packet reception is delayed, delaying the response, due to a defect in the XSCF-LAN hardware settings.
Workaround There is no effective workaround.