The following table lists the problems resolved in XCP 2092.
Table 3-42  Problems Resolved in XCP 2092
RTI No. RTIF2-140115-001
Model SPARC M10-1, SPARC M10-4, SPARC M10-4S
Description If a failure occurs in the PCI expansion unit, all the domains that are situated in the physical partition (PPAR) that is connected to the PCI expansion unit are shut down.
Workaround There is no effective workaround.
RTI No. RTIF2-140110-001
Model SPARC M10-4S
Description In a SPARC M10-4S (with crossbar box) configuration, the following event log, which notifies power off, is not registered.
BB#xx was stopped by power failure. Power failure date is yyyy/mm/dd hh:mm:ss
Workaround There is no effective workaround.
RTI No. RTIF2-140110-002
Model SPARC M10-1, SPARC M10-4, SPARC M10-4S
Description When the flashupdate(8) command is executed, only occasionally, the XSCF may not start up.
Workaround There is no effective workaround.
Contact a field engineer if this problem occurs.
RTI No. RTIF2-131213-015
Model SPARC M10-4S
Description In case, all of the three conditions below are met on a physical partition, the crossbar unit (XBU) error "Msg: XB-XB interface fatal error" is detected.
[Condition 1] The physical partition consists of several SPARC M10-4S chassis.
[Condition 2] The XSCF BB control cables that are connected to the SPARC M10-4S chassis are either defective or have been disconnected. In such a case, the "Msg: BB control cable detected unexpected" error log is registered.
[Condition 3] The physical partition was rebooted due to a hardware failure, the poweron(8) or reset(8) command was executed.
Moreover, the XSCF had either rebooted the physical partition due to a hardware failure or had performed retrial of the poweron(8) or reset(8) command when this symptom previously occurred.
Workaround There is no effective workaround.
Do not execute the poweron(8) or the reset(8) command while the XSCF BB control cable is disconnected.
[How to restore]
If a hardware failure occurred, power off and on the physical partition.
If the XSCF is performing retrial operations, execute the poweroff -f -p ppar-id command to forcibly power off the physical partition. After that power it on.