Problems Resolved in Version 1330 of the PCI Expansion Unit Firmware


Problems Resolved in Version 1330 of the PCI Expansion Unit Firmware
The following table lists the problems resolved in version 1330 of the PCI expansion unit firmware.
Table 6-3  Problems Resolved in Version 1330 of the PCI Expansion Unit Firmware
RTI No. RTIF2-190902-001
Model SPARC M12-1, SPARC M12-2, SPARC M12-2S
Description You cannot use the following link cables (optical) when PCI expansion unit firmware 1310 or earlier is being used:
Part number: 8204008 and CA66117-1002
These numbers are found on labels on the link cables (optical).
If one of these cables is connected when the PCI expansion unit is powered on, the following error occurs:
PCI Express lane is degraded
PCI Express link speed is degraded
Workaround To use link cables (optical) with PCI expansion unit firmware 1310 or earlier, make sure to use the ones with both "7061047" and "CA66053-1002" printed on their labels. With PCI expansion unit firmware 1330 or later, you can use all link cables.
RTI No. RTIF2-190716-003
Model SPARC M12-1, SPARC M12-2, SPARC M12-2S
Description The CHECK LED of the PCI expansion unit does not go on when the input power to the power supply unit (PSU) of the PCI expansion unit is turned off. Likewise, if an error occurs in the primary circuit, the LED does not go on.
Workaround There is no effective workaround.