Problems Resolved in XCP 3100
Problems Resolved in XCP 3100
The following table lists the problems resolved in XCP 3100.
RTI No. | RTIF2-210506-003 |
Model | SPARC M12-1, SPARC M12-2, SPARC M12-2S |
Description | Security fixes. (CVE-2016-4429, CVE-2017-16931, CVE-2017-5461, CVE-2018-7183, CVE-2020-11868) For details, see the Oracle website relating to the following: Critical Patch Updates |
Workaround | Update the XCP firmware to XCP 3100 or later. |
RTI No. | RTIF2-210204-002 |
Model | SPARC M12-2S |
Description | When a dynamic reconfiguration of a physical partion fails, register values may be corrupted. This may cause a logical domain to panic. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-210204-004 |
Model | SPARC M12-2S |
Description | Rebooting multiple logical domains simultaneously during dynamic reconfiguration of the physical partition may corrupt register values to cause Hypervisor to abort. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-210203-002 |
Model | SPARC M12-2S |
Description | PPAR DR may fail because Hypervisor does not report its completion to the XSCF. |
Workaround | There is no effective workaround. |
RTI No. | RTIF2-201109-028 |
Model | SPARC M12-1, SPARC M12-2, SPARC M12-2S |
Description | In some very rare cases, any of the following may occur when XSCF Web is used. (1) The "SCF panic detected" error is detected and the XSCF is rebooted. (2) The physical partition cannot be powered on, powered off, or restarted. (3) Nothing can be set or displayed with XSCF shell commands or XSCF Web. |
Workaround | There is no effective workaround. [How to restore] Perform the following procedure for (2) or (3) in [Description]. 1. If Oracle Solaris is running, shut down every Oracle Solaris instance. 2. Confirm that Oracle Solaris has been shut down, and then turn off and on (AC OFF/ON) the input power of the system. |
RTI No. | RTIF2-201109-029 |
Model | SPARC M12-1, SPARC M12-2, SPARC M12-2S |
Description | Security fixes. (CVE-2020-1968, CVE-2018-0737, CVE-2018-0739, CVE-2017-3735) For details, see the Oracle website relating to the following: Critical Patch Updates |
Workaround | Update the XCP firmware to XCP 3100 or later. |
RTI No. | RTIF2-200528-001 |
Model | SPARC M12-2S |
Description | A logical domain may panic with the following message when dynamic reconfiguration of the physical partition with the deleteboard(8) command is performed. send_mondo_set: unexpected hypervisor error 0x2 while sending a mondo to cpuid(s): 0x17 panic[cpu29]/thread=c400630b7740: send_mondo_set: unexpected hypervisor error |
Workaround | There is no effective workaround. |