Skip to main content

Problems Resolved in XCP 4011


Problems Resolved in XCP 4011
The following table lists the problems resolved in XCP 4011.
Table 3-9  Problems Resolved in XCP 4011
RTI No. RTIF2-220712-001
Model SPARC M12-1, SPARC M12-2, SPARC M12-2S
Description Security fixes.
(CVE-2022-23218, CVE-2022-23219)
For details, see the Oracle website relating to the following:
Critical Patch Updates
Workaround Update the XCP firmware to XCP 4011 or later.
RTI No. RTIF2-220411-002
Model SPARC M12-1, SPARC M12-2, SPARC M12-2S
Description Hypervisor might abort if a physical partition with power-saving operation enabled has a virtual CPU (vcpu) not assigned to any logical domain.
Workaround There is no effective workaround.
RTI No. RTIF2-220408-001
Model SPARC M12-1, SPARC M12-2, SPARC M12-2S
Description An XSCF panic reboot may occur after the XSCF has been running continuously for about two years in an environment where the temperatures of parts frequently fluctuate due to the effects of the ambient temperature, system load, etc.
Workaround There is no effective workaround.
RTI No. RTIF2-220408-003
Model SPARC M12-1, SPARC M12-2, SPARC M12-2S
Description XSCF Web cannot suppress and prevent import of XCP 3xxx firmware.
Workaround There is no effective workaround.
RTI No. RTIF2-220404-001
Model SPARC M12-1, SPARC M12-2, SPARC M12-2S
Description Security fix for XSCF Web.
Workaround Update the XCP firmware to XCP 4011 or later.