Restrictions on Replacing a Crossbar Box (Only for SPARC M12-2S)
Restrictions on Replacing a Crossbar Box (Only for SPARC M12-2S)
Replacement of a crossbar box using the replacefru(8) command is not supported at present. To replace a crossbar box, perform the following procedure:
- Execute the showhardconf command to confirm that the crossbar box to be replaced is not the master chassis.
The crossbar box with the "Role:Master" indication is the master chassis.
XSCF> showhardconf : XBBOX#80 Status:Normal; Role:Master; Ver:2038h; Serial:2111206001; : |
- If the crossbar box to be replaced is the master chassis, first execute the switchscf command to switch the box to standby.
XSCF> switchscf -y -t Standby |
- The master XSCF is switched. Log in to the XSCF again.
- Power off the physical partition (PPAR) that uses the crossbar box, and then power off the crossbar box to be replaced.
Confirm that the Power-LED on the operation panel of the crossbar box is turned off. - Disconnect the power supply to the crossbar box to be replaced, and then replace it.
Note - Although error logs for the crossbar box to be replaced are registered when the input power supply is disconnected, they can safely be ignored. |
- Connect the power cord of the crossbar box to the input power supply.
For details, see "5.3 Connecting Cables to the Crossbar Box" in the Fujitsu SPARC M12-2S Installation Guide.
Wait until the STANDBY-LED on the operation panel of the crossbar box goes on. - Execute the diagxbu command to perform diagnosis of the newly installed crossbar box.
XSCF> diagxbu -y -b XX -t YY -t ZZ |
- Specify the BB-IDs (00 to 15) of the powered-off SPARC M12-2S in XX, YY, and ZZ.
- Execute the showlogs command to confirm that no error occurred during the diagnosis.
XSCF> showlogs error |
- Confirm that there are no faulty components.
XSCF> showstatus |
< Previous Page | Next Page >