Skip to main content
  1. Home >
  2. Products >
  3. Computing Products >
  4. Servers >
  5. Fujitsu SPARC servers >
  6. Downloads >
  7. User Manuals >
  8. Fujitsu SPARC M12-2 Installation Guide >
  9. A.2.3 Checking Information on a Component Where a Failure or Degradation Occurred

A.2.3 Checking Information on a Component Where a Failure or Degradation Occurred


A.2.3 Checking Information on a Component Where a Failure or Degradation Occurred
Use the showstatus command to check information on a degraded unit among the FRUs composing the system.
showstatus command
The command displays information on each unit where a failure has occurred and the units on higher layers, from among the field replaceable units composing the system. The mark indicating the status (*) appears at the beginning of the line of the displayed unit. Status displays the unit status.
  1. Status: Description
  2. Faulted: Non-operational status of the relevant component due to failure
  3. Degraded: A part of the unit has failed, but the unit continues in operation.
  4. Deconfigured: Including its components on the lower layers, the unit is in a normal condition, but it has been degraded due to the influence of a failure or degradation of another unit.
  5. Maintenance: Maintenance work in progress. The replacefru command is in operation.
Example: Display example where a CPU and memory of the CPU memory unit (lower) of BB#00 are degraded because of a failure
XSCF> showstatus
  BB#00;

CMUL Status:Normal;
* CPU#0 Status:Faulted;
* MEM#00A Status:Faulted;