A.1 Understanding the Usual Problems and Their Corrective Actions
A.1 Understanding the Usual Problems and Their Corrective Actions
If system operation is not normal during installation work, you may wonder whether there was a failure. In such cases, inspect the following items and take corrective measures accordingly.
Case | Possible Cause | Corrective Action |
---|---|---|
The input power cannot be turned on. | The power cord is disconnected. | Connect the power cord correctly. |
The breaker on the distribution board is turned off. | Turn on the breaker. | |
The system management terminal does not display the login prompt. | The serial cable is not connected to the serial port. | Connect the serial cable correctly to the serial port on the rear of the SPARC M12-2. See Figure 4-1 in "4.1 Connecting Cables to the SPARC M12-2." |
After a connection is established for the serial connection to the XSCF, the [Enter] key must be pressed. | After the serial connection is established, press the [Enter] key. See "5.3 Logging In to the XSCF." |
|
There are cases where the XSCF shell prompt does not appear after the console command was executed to terminate the previous established serial connection. | If the XSCF shell prompt does not appear, enter "#." to move from the console to the XSCF shell. | |
The sethostname command changed the host name of the XSCF, but this change was not reflected. | This is because the applynetwork command was not executed after the sethostname command was executed. | After changing the host name with the sethostname command, execute the applynetwork command, and reboot the XSCF with the rebootxscf command. |