Skip to main content
  1. Home >
  2. Products >
  3. Computing Products >
  4. Servers >
  5. Fujitsu SPARC servers >
  6. Downloads >
  7. User Manuals >
  8. Fujitsu SPARC M12-2 Installation Guide >
  9. 2.8.1 Redundant Configuration of Power Supply Units

2.8.1 Redundant Configuration of Power Supply Units


2.8.1 Redundant Configuration of Power Supply Units
The SPARC M12-2 has power supply units in a 2+2 redundant configuration as standard. If failures occur in two power supply units, the system can still continue to operate with the remaining two power supply units. However, if a failure occurs in the external power supply, the system stops.
Figure 2-4 shows a power supply system with redundant power supply connections.

When connecting the power cords to the same power supply system, make sure to connect each power cord to the circuit breaker in a one-to-one manner.
Figure 2-4  Power Supply System With Redundant Power Supply Connections
Figure 2-4  Power Supply System With Redundant Power Supply Connections