A.2.1 Checking the Component Status


A.2.1 Checking the Component Status
Use the showhardconf command to check the status of each field replaceable unit (FRU). The displayed information is as follows:
  1. Current configuration and status
  2. Quantities of mounted FRUs by FRU type, such as CPU, memory, and PCIe card
  3. Physical partition (PPAR) information
  4. PCI expansion unit information (displayed only when the power to the physical partition is on)
  5. PCIe card information (displayed only when the power to the physical partition is on)
showhardconf command
Use the showhardconf command to check the system hardware configuration and the status of each component.
A displayed asterisk (*) indicates the fault location of a unit where a failure or degradation occurred.
Status displays the following statuses.
  1. Faulted: Non-operational status of the relevant component due to failure
  2. Degraded: A part of the unit has failed, but the unit continues in operation.
  3. Deconfigured: Including its components on the lower layers, the unit is in a normal condition, but it has been degraded due to the influence of a failure or degradation of another unit.
  4. Maintenance: Maintenance work in progress. The replacefru command is running.
  5. Normal: Normal status
Example: SPARC M12-1 display example
XSCF> showhardconf -M
SPARC M12-1;
+ Serial:TZ41702014; Operator_Panel_Switch:Service;
+ System_Power:Off; System_Phase:Cabinet Power Off;
Partition#0 PPAR_Status:Powered Off;
MBU Status:Normal; Ver:3025h; Serial:TZ1701D01B ;
+ FRU-Part-Number:CA08208-D001 A0 /9999999 ;
+ Power_Supply_System:Dual;
+ Memory_Size:256 GB; Type: C ;
CPU#0 Status:Normal; Ver:4242h; Serial:00070376;
+ Freq:3.200 GHz; Type:0x30;
+ Core:6; Strand:8;
MEM#00A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC 00-316D5587;
+ Type:83; Size:16 GB;
MEM#01A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC 00-316D558D;
+ Type:83; Size:16 GB;
MEM#02A Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-12218825;
+ Type:83; Size:16 GB;
MEM#03A Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-1221887D;
+ Type:83; Size:16 GB;
MEM#10A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC 00-316D5533;
+ Type:83; Size:16 GB;
MEM#11A Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC 00-316D5606;
+ Type:83; Size:16 GB;
MEM#12A Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-1221884F;
+ Type:83; Size:16 GB;
MEM#13A Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-12218883;
+ Type:83; Size:16 GB;
MEM#00B Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC 00-316D5D34;
+ Type:83; Size:16 GB;
MEM#01B Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC 00-316D5586;
+ Type:83; Size:16 GB;
MEM#02B Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-12218824;
+ Type:83; Size:16 GB;
MEM#03B Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-12218884;
+ Type:83; Size:16 GB;
MEM#10B Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC 00-316D558C;
+ Type:83; Size:16 GB;
MEM#11B Status:Normal;
+ Code:ce8002M393A2K40BB1-CRC 00-316D552F;
+ Type:83; Size:16 GB;
MEM#12B Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-1221872C;
+ Type:83; Size:16 GB;
MEM#13B Status:Normal;
+ Code:2c800f18ASF2G72PZ-2G3B1 31-12218853;
+ Type:83; Size:16 GB;
OPNL Status:Normal; Ver:0101h; Serial:TZ1637F0E5 ;
+ FRU-Part-Number:CA07363-D101 A0 /7060786 ;
+ Type: A ;
PSUBP Status:Normal; Ver:0101h; Serial:TZ1649P048 ;
+ FRU-Part-Number:CA20366-B15X 005AB/7087517 ;
+ Type: A ;
PSU#0 Status:Normal; Ver:303141h; Serial:HLKD1653000150;
+ FRU-Part-Number:CA01022-0755-M/0000000 ;
+ Power_Status:OFF; AC:200 V; Type: B ;
PSU#1 Status:Normal; Ver:303141h; Serial:HLKD1653000271;
+ FRU-Part-Number:CA01022-0755-M/0000000 ;
+ Power_Status:OFF; AC:200 V; Type: B ;
FANU#0 Status:Normal; Type: A ;
FANU#1 Status:Normal; Type: A ;
FANU#2 Status:Normal; Type: A ;
FANU#3 Status:Normal; Type: A ;
FANU#4 Status:Normal; Type: A ;
FANU#5 Status:Normal; Type: A ;
FANU#6 Status:Normal; Type: A ;
HDDBP Status:Normal; Type: A ;
showhardconf -u command
Use the showhardconf command with the -u option to display the quantity of each type of mounted field replaceable unit.
The CPU modules are displayed with the operating frequency, and the memory units are displayed with the capacity per memory. If the option is omitted, the command displays the current configuration information, status information, and physical partition (PPAR) information for each field replaceable unit.
Example: SPARC M12-1 display example
XSCF> showhardconf -u
SPARC M12-1; Memory_Size:64 GB;
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| MBU | 1 |
| Type:C | ( 1) |
| CPU | 1 |
| Freq:3.200 GHz; | ( 1) |
| MEM | 4 |
| Type:83; Size:16 GB; | ( 4) |
| PCICARD | 0 |
| LINKCARD | 0 |
| PCIBOX | 0 |
| IOB | 0 |
| LINKBOARD | 0 |
| PCI | 0 |
| FANBP | 0 |
| PSU | 0 |
| FAN | 0 |
| OPNL | 1 |
| Type:A | ( 1) |
| PSUBP | 1 |
| Type:A | ( 1) |
| PSU | 2 |
| Type:B | ( 2) |
| FANU | 7 |
| HDDBP | 1 |
+-----------------------------------+------------+