2.9.1 Electrical Specifications
2.9.1 Electrical Specifications
Item | Specification | |
---|---|---|
Input Voltage of 100 to 120 VAC | Input Voltage of 200 to 240 VAC | |
Number of power cords | 2 (1 for each PSU) |
2 (1 for each PSU) |
Power cord length (*1) | Maximum length of 3.0 m (9.8 ft.) | Maximum length of 3.0 m (9.8 ft.) |
Redundancy | 1+1 redundant configuration | 1+1 redundant configuration |
Frequency | 50 Hz/60 Hz, single phase |
50 Hz/60 Hz, single phase |
Maximum input current (*2) | 8.1 A | 4.0 A |
Maximum power consumption | 785 W | 774 W |
Apparent power | 809 VA |
798 VA |
Rush current (*3) | 40 A peak or less |
40 A peak or less |
Leakage current (*3) | 1.75 mA or less | 1.75 mA or less |
*1 The SPARC M12-1 is pulled out to perform maintenance. Therefore, you need to consider an extra length of 1.5 m when ordering the power cord. *2 The current that flows through each power cord in a redundant configuration is half the value listed in Table 2-8. *3 The value is per power cord. |
Item | Specification | |
---|---|---|
Input Voltage of 100 to 120 VAC | Input Voltage of 200 to 240 VAC | |
Number of power cords | 2 (1 for each PSU) |
2 (1 for each PSU) |
Power cord length | Maximum length of 3.0 m (9.8 ft.) | Maximum length of 3.0 m (9.8 ft.) |
Redundancy | 1+1 redundant configuration | 1+1 redundant configuration |
Frequency | 50 Hz/60 Hz, single phase |
50 Hz/60 Hz, single phase |
Maximum input current (*1) | 2.9 A | 1.4 A |
Maximum power consumption | 279 W | 270 W |
Apparent power | 284 VA |
276 VA |
Rush current (*2) | 40 A peak or less |
40 A peak or less |
Leakage current (*2) | 1.75 mA | 1.75 mA |
*1 The current that flows through each power cord in a redundant configuration is half the value listed in Table 2-9. *2 The value is per power cord. |
< Previous Page | Next Page >