5.8 Checking the Component Status
5.8 Checking the Component Status
This section describes the procedure for checking the configuration, status, and quantities of the mounted field replaceable units (FRUs).
- Execute the showhardconf command.
The command displays all the FRUs mounted in the chassis and their status. However, it does not display the status of I/O-related components such as PCIe cards and PCI expansion units while the system power is off.
Example: SPARC M12-1 display example
XSCF> showhardconf -M SPARC M12-1; + Serial:xxxxxxxxxx; Operator_Panel_Switch:Service; + System_Power:Off; System_Phase:Cabinet Power Off; Partition#0 PPAR_Status:Powered Off; MBU Status:Normal; Ver:3025h; Serial:TZ1710D00R ; + FRU-Part-Number:CA08208-D001 A1 /9999999 ; + Power_Supply_System: ; + Memory_Size:64 GB; Type: C ; CPU#0 Status:Normal; Ver:4242h; Serial:00070592; + Freq:3.200 GHz; Type:0x30; + Core:6; Strand:8; MEM#00A Status:Normal; + Code:2c800f18ASF2G72PZ-2G3B1 31-1268F2DA; + Type:83; Size:16 GB; MEM#01A Status:Normal; + Code:2c800f18ASF2G72PZ-2G3B1 31-1268F2F9; + Type:83; Size:16 GB; MEM#02A Status:Normal; + Code:2c800f18ASF2G72PZ-2G3B1 31-1268F2DB; + Type:83; Size:16 GB; MEM#03A Status:Normal; + Code:2c800f18ASF2G72PZ-2G3B1 31-1268F2E8; + Type:83; Size:16 GB; Omitted |
- Confirm that no FRU has an asterisk (*) displayed in front of it.
The asterisk (*) is a mark indicating the abnormal state of a FRU, where an error or degradation occurred.
If a failure has occurred in any unit, see "A.2.2 Checking the Contents of Logs" and "A.2.3 Checking Information on a Component Where a Failure or Degradation Occurred." - Execute the showhardconf -u command.
The command displays the quantities of mounted FRUs. However, it does not display the quantities of I/O-related components such as PCIe cards and PCI expansion units while the system power is off.
Example: SPARC M12-1 display example
XSCF> showhardconf -u SPARC M12-1; Memory_Size:64 GB; +-----------------------------------+------------+ | FRU | Quantity | +-----------------------------------+------------+ | MBU | 1 | | Type:C | ( 1) | | CPU | 1 | | Freq:3.200 GHz; | ( 1) | | MEM | 4 | | Type:83; Size:16 GB; | ( 4) | | PCICARD | 0 | | LINKCARD | 0 | | PCIBOX | 0 | | IOB | 0 | | LINKBOARD | 0 | | PCI | 0 | | FANBP | 0 | | PSU | 0 | | FAN | 0 | | OPNL | 1 | | Type:A | ( 1) | | PSUBP | 1 | | Type:A | ( 1) | | PSU | 2 | | Type:B | ( 2) | | FANU | 7 | | HDDBP | 1 | +-----------------------------------+------------+ |
- Execute the showlogs error command.
Confirm that no error is displayed. If an error is displayed, see "A.2.2 Checking the Contents of Logs."
XSCF> showlogs error |
- Execute the showstatus command.
When there is no problem, the command displays nothing.
If a failure has occurred in any unit, an asterisk (*) and the unit status are displayed. See "A.2.3 Checking Information on a Component Where a Failure or Degradation Occurred."
XSCF> showstatus |
- To implement the initial system settings, go to "Chapter 6 Making the Initial System Settings." Otherwise, log out of the XSCF.
< Previous Page | Next Page >